Step 5
Press the mode return button. This will take you out of programming and back to the main screen. If the current time is
within an on cycle there may be a slight delay of up to 20 second before the heating will activate.
TO SET THE TEMPERATURE FOR PROGRAM TIMES
The current model of the TH115 thermostat can be switched between FLOOR sensor (F displayed on screen) and AIR
sensor with floor limit (AF). Most people prefer to set the floor temperature, but if you wish to switch between the two,
please see item 2 (configuration) on manufacturers instruction. Switch 3 on the face plate will switch between floor
sensing & sir sensing.
Using the up and down arrow keys set the temperature you want for the on cycle. e.g. 26°C. Then press and hold the
Sun button for a few seconds. The display will show a sun symbol in the centre of the screen, indicating that the "on"
temperature has been set.
Repeat the procedure above to set the temperature for the off cycle. e.g.. 18°C by pressing and holding the half
moon button. The display will show a half moon symbol in the centre of the screen, indicating that the "off" temperature
has been set.
The suitcase symbol is for when you go on holiday or for use in the summer time when you are not using the system. This
can set as low as 5°C. To set the temperature for the vacation cycle. e.g. 5°C. by pressing and holding the Suitcase
button. The display will show a suitcase symbol in the centre of the screen, indicating that the "vacation" temperature has
been set.
When you have finished setting the temperatures & times, press the mode button & ensure the clock is displayed. If the
clock is flashing, simply press mode once more & it will stop flashing.
RECOMMENDATIONS
If you floor heating is installed in a bathroom, we would recommend setting the timer for early morning (say 0400 hrs) so
that the room is comfortable when you get up & then depending on your location/comfort levels, set the off time & second
on/off time to suit your lifestyle.
For under-tile or in screed heating we would recommend setting the timer to start approx 1-2 hours before you are usually
in the room
If you have floor heating installed in the slab it will usually take several hours to heat up & so this is particularly well
suited to using a smart meter to take advantage of 'off peak' prices. If you have a smart meter, we recommend that you
operate the heating overnight to coincide with the lowest energy cost – the heat will then be stored in the slab for several
hours & may not need to come on again until the following night. Current Synergy off-peak times are 2100hrs – 0700 hrs,
so this is what you should chose as program 1 & 2 times (or say midnight to 0700 hrs if you are not usually up late)
If you are using floor heating as your only heating, then during cold spells you may need to 'boost' the heating in the
afternoon so that the house remains warm during the evening. To do this we would recommend that you set the second
on/off times (program 3 & 4) from say 1500 hrs – 1700 hrs. This is the 'shoulder' rate & is currently around the same cost
as the standard tariff – this should give you a comfortable room for the rest of the evening until the main off-peak time
starts again.
With a smart meter, you should always try to avoid operating the heating during the peak winter times of 1700 – 2100 hrs
Monday-Friday. Weekends are of course at a reduced rate during the day & night.
If you require any assistance, please contact Radiant Floor Heating, Wangara on 08 9302 4140 or visit our
www.radiantfloorheating.com.au