Control Module
TH132 A/F/AF
Owner's Guide
Thank you for choosing the Aube TH132, a programma-
ble thermostat that provides both energy savings and total
comfort.
Install the Control Module
Align the bracket tabs on the control module with the
holes located on top of the power base.
This control module must be installed on a PB130 series
power base.
Control module
Air vents
Power base
Note:
Keep the thermostat's air vents clean and free from
obstructions.
Note:
The screw cannot be removed completely.
TH132 Description
DAY/HOUR/MIN—Set the day and clock settings.
PGM—Program the schedule (programs).
MODE—Select the operating mode.
RETURN—To exit a function.
To configure temperature setpoints:
,
Comfort
Economy and
Adjust the floor temperature limit (AF only).
—Increase and decrease temperature.
—Indicates the number of the current
program when Automatic mode is enabled.
Current operating mode (auto
Auto mode, the program's associated setpoint icon is
also displayed (
).
Indicates the room OR floor temperature.
Heating indicators (see "Temperature Control"
below).
First Power ON
On the first installation, the screen displays:
0:00, MO,
and temperature (room/floor).
For Floor Heating Installations:
One of the two following messages may be dis-
played when a problem occurs:
Air vents
LO: The floor temperature is below 32°F (0°C), or
the temperature sensor is defective, or not
connected.
The heating indicator
is displayed and
the relay is closed (energized).
HI: The floor temperature is above
140°F (60°C), or the temperature sensor is
defective.
Set the Time and Day
Set the time (HOUR - MIN).
Set the day (DAY).
If you remove the module from its base for more than
2 hours, the time and day will have to be reprogrammed.
Models Overview
TH132-A
This model has been designed to control a room's ambi-
ent temperature.
The TH132-A has one temperature sensor located in the
control module.
TH132-AF
Vacation.
This model is designed to use a floor sensor to control the
room temperature.
The TH132-AF has two temperature sensors:
•
The first one, installed in the control module, controls
the ambient temperature.
/
•
The second one, installed in the floor (and connected
manual
). In
to the power base), limits the temperature of the floor
(the default setting of this limit is 82°F).
TH132-F
This model is designed to control floor heating systems.
The TH132-F has one temperature sensor installed in the
floor (sensor is connected to the power base).
Adjust the Temperature Setpoints
Comfort
and Economy
These setpoints are associated with the schedule's pro-
grams (prog. 1 & 3 = Comfort, prog. 2 & 4 = Economy)
and are preprogrammed as follows:
A & AF models—
F model—
82°F,
To modify a setpoint:
Set the temperature using
or
button until it is displayed on the screen.
Press MODE/RETURN to exit.
Vacation Setpoint
The vacation setpoint is associated to the Vacation oper-
ating mode and is preprogrammed to 50°F. To modify this
setpoint, repeat above steps.
Floor Temperature Setpoint (AF model only)
The floor temperature limit is preprogrammed to 82°F to
avoid damage to your floor.
To modify, press the adjustment button (below
pointed object, set the desired temperature using
press MODE/RETURN to exit.
Configure the Switches
The TH132 has two switches, located on the upper-left
part on the rear of the control module, which are used to
set the following options:
Early Start
When the Early Start function is enabled (disabled by
default), the TH132 calculates the optimum system start
time to obtain the desired temperature by the set time. To
enable this function:
Position switch #1 down.
Note:
When this function is enabled, the
system can be activated before the pro-
gram's start time.
Temperature Display
By default, the TH132 displays the temperature in °C. If
you wish to change to °F:
Position switch #2 up.
Note:
When you switch from °C to °F or vice
versa, the
redefined.
Select the Operating Mode
Setpoints
The TH132 offers three operating modes:
Automatic —
Press MODE to select
program number is displayed.
68°F,
64°F
You can temporarily bypass the current
68°F
program by setting a specific temperature setpoint
or by selecting one of the pre-defined setpoint
buttons (
and press and hold the
until the beginning of the next program.
Manual
Press MODE to select
Set temperature
defined setpoint buttons (
Vacation
during a prolonged absence.
Press
) using a
and
,
and
setpoints must be
Executes the schedule.
. The current
). The new setpoint will be maintained
—Maintains a constant temperature.
.
or select one of the pre-
).
—Maintains the Vacation setpoint
.
400-132-000-A