Basic Operations
1. Power Input. This Cube unit requires US 240V power with L1, L2, neutral, and ground. Please 
ensure the wiring in the L14‐30R power input connector (plug) is correct.  
2. Temperature Controller. The EZBoil® temperature controller will turn on once the Cube is 
connected to a 240V power. Consult the user manual of the EZBoil controller to get familiar 
with how to program the controller.  
3. Sensor Input. Connect a PT100 RTD sensor to the XLRCON‐M port on the back panel of the 
Cube unit. The controller should show current temperature reading from the sensor. Before a 
PT100 RTD sensor is connected, the controller will show error code "ORAL" and "932" 
alternatively. 
4. Output Indicator. On the EZBoil controller, the green LED indicator "OUT" shows the power 
output status.   
5. AUX Output Sockets. The AUX1 socket and AUX2 socket will supply 120V power if the 
corresponding AUX switch is turned to the ON position. Turn AUX switches to the OFF position 
if these 120V sockets are not in use. 
6. Main Switch. The Main Switch (32A 2‐pole circuit breaker) controls the power to the HEATER 
socket (L6‐30R). Flip the Main Switch to the ON position will enable the 240V power to the 
HEATER socket. In situations where you need to cutoff power to the 240V heater socket or 
when the solid‐state relay is shorted, flip this Main Switch to OFF position.  
 
 
(End) 
 
 
 
 
 
 
No part of this manual shall be copied, reproduced, or transmitted in any way without the prior, written consent of Auber Instruments. Auber 
Instruments retains the exclusive rights to all information included in this document. 
 
 
 
Auber Instruments 
5755 North Point Parkway, Suite 99 
Alpharetta, GA 30022, USA 
www.auberins.com 
E‐mail: [email protected] Tel: 770‐569‐8420 
 
Copyright 2007‐2022, Auber Instruments. All Rights Reserved. 
Page 2 of 2 
www.auberins.com