- ページ 12

温度コントローラー Auber Instruments WS-1211GPHのPDF クイックマニュアルをオンラインで閲覧またはダウンロードできます。Auber Instruments WS-1211GPH 12 ページ。 Programmable precision pid temperature controller

Auber Instruments WS-1211GPH クイックマニュアル
4) Change PrG=on, current b1 recipe is:
C-1=200, F-1=2.0;
C-2=190, F-2=160;
C-3= 130, F-3=30.0.

9. Factory reset function

WARNING! This function will restore all the parameters (including receipts in the memory) back
to factory default. Please write all the necessary settings down. For details on how to access
these parameters, please check section 9 of the main instruction manual.
To reset, under the normal operating mode, press and hold SET key for 2 seconds until LED
display "LoCK", and then release the SET key. The display will show "0" then. Use "+" key to
adjust the number to 666 and press SET key again to confirm. The display will show as "lnlE",
then it will show as "off". Press "+" key once to change "off" to "on". Press SET key to confirm
factory reset. The display will show "----" then "8.8.8.8." When you see this display back to normal
operating mode, factory reset completed.
Please note: In older versions, it may show InIE options as "y" or "n", instead of "on",
"off". To reset, please select "y".
Copyright © 2021 Auber Instruments Inc. All rights reserved.
No part of this datasheet shall be copied, reproduced, or transmitted in any way without the prior, written consent
of Auber Instruments. Auber Instruments retains the exclusive rights to all information included in this document.
12