コントローラー Auber Instruments EZboil DSPR310DのPDF クイックマニュアルをオンラインで閲覧またはダウンロードできます。Auber Instruments EZboil DSPR310D 2 ページ。 For step mashing and boiling process automation
Auber Instruments EZboil DSPR310D にも: 取扱説明書 (14 ページ)

AUBER INSTRUMENTS
1. Quick list of key functions:
1). Key A (or Key RUN): In mashing mode, key A is used to start or resume the program; in boiling mode, key A is used to start the SSR power output, and also start
or resume the timer at same time (if timer is enabled). Press key A momentarily to start or resume. In DSPR310D, Key A can also be used to mute the built-in buzzer
in specific situation (if you set relay mode RL to ALbE). For details, please check section 5.3.3 in page 4 of its main manual.
2). Key B (or Key HOLD/STOP): In mashing mode, key B is used to hold or stop the program. Press Key B momentarily to hold the current program. Press and hold
key B for 5s to stop the program. In boiling mode, key B is used to hold or stop the timer and power output: When timer is disabled, press key B momentarily to turn off
the power output; when timer is enabled, press key B momentarily to hold the timer. Press and hold key B for 5s to turn off the power output and stop the timer.
3). Rotary Knob: You can rotate this knob clockwise or counter-clockwise to increase/decrease the value. This knob is also needed to enter the setting menus. Push
down this knob momentarily to enter the first layer of menu, which you can reset the timer, or change between mashing and boiling modes. Push down and hold this
knob for 5s to enter second layer of menu, which you can adjust step mashing temperature & time profile, timer events in boiling mode and also other advanced alarm
& system settings. For details, please check its main manual.
2. FAQs:
1) Q: What is the difference between "HOLD" and "STOP"?
A: "HOLD" will maintain your target at previous set temperature in mashing mode, and pause your timer counting in boiling mode (if timer is enabled). For example,
assuming the set temperature is 150F before "HOLD" action, after "HOLD", the controller will maintain at 150F as well. In boiling mode, after you pause your timer, you
can also adjust the power output percentage. To resume the timer, you can press Key A momentarily.
"STOP" will stop the whole program and disable the output in both mashing and boiling modes. There will be no output then, no matter what status it is before "STOP"
action. After "STOP", you cannot resume the program/timer, but only restart the program/timer from the beginning. To restart, you can press Key A momentarily.
2) Q: What is the difference between "END" and "STOP"?
A: "END" is triggered by the controller. It means the whole step program or timer event is completed. After program/timer ends, the power output can be configured
either to continue heating, or shut off. It is controlled by the parameter EO in step mashing mode, or bEO in boiling mode. If you want to run another step mashing
program, you need to 1) simply reboot the controller, or 2) change "END" status to "STOP" status by the knob at first, then push Key A to restart: Push down the knob
momentarily and change "rst" to "y", then push down the knob again to confirm.
"STOP" is triggered by key function (by holding key B), or by programmed step (you can program specific step to "STOP" in step mashing mode). When program/timer
is stopped, output will be disabled. Once "STOP", you can only restart the program from the first step (press Key A), and you cannot go to the next step after that
"STOP" step.
3) Q: How to start the timer in boiling mode?
A: To start the timer in boiling mode, three criterions need to be met:
1). Timer must be enabled in parameter settings: tF = ON.
2). The controller cannot be under STOP/HOLD status. If you see the display flashes "STOP" or "HOLD", you need to press key A momentarily to start or resume the
program.
3). Controller's reading temperature (top display) must be higher than the value of btsp (boiling timer start temperature).
Tip: When timer is started, you will hear the special beeping notification.
3. Program Examples:
1) Step mashing program (under menu "PROG", section 6.2 in page 5 of its main manual):
Each step has two parameters. C-X is the set temperature for that step, and t-X is the time duration for that step, where X is the step number. This program will control
at the temperature of 122F for 30 minutes at first. Then raise the temperature to 140F and hold there for 20 minutes. Then raise the temperature to 154F and hold there
for 40 minutes. Finally raise the temperature to 168F and hold there for 15 minutes. Then end the program (timer is set to 0 for step 5 - 8).
2017.07
EZboil DSPR310D Quick Guide
Version 1.0 (Oct, 2017)
Parameter
Initial Setting
C-1
122
C-2
140
C-3
154
C-4
168
C-5
50
C-6
50
C-7
50
C-8
50
Table 1. Step mashing program example.
Parameter
Initial Setting
t-1
00:30
t-2
00:20
t-3
00:40
t-4
00:15
t-5
00:00
t-6
00:00
t-7
00:00
t-8
00:00
WWW.AUBERINS.COM
P1/2