7) Buttons: Local Settings
1) EDIT
Clicking the EDIT button will scroll through to display the current status for each of the 3 parameters
for the selected output: TYPE (output type), DIV (clock division/multiple) and OFFS (phase offset).
The white LED above the panel title will illuminate to show which of the 3 parameters has been
selected and is ready to edit.
The vertical row of 12 white LEDs will also update and illuminate to show which option has been
selected for the selected parameter.
These 3 LEDs will also update when the OUTPUT: TYPE, CLOCK DIV/MULT or PHASE OFFSET
KNOBS are moved.
2) OPTION
Each output type has an option. Clicking the OPTION button will turn the option on or off (output
types 1-8), activate looping (output types 9-10) or scroll through (output types 11-12).
For output types with only one option – the white LED above the OPTION button will illuminate
to show whether the option is selected (LED on) or not (LED off).
For output types with a looping option – the white LED above the OPTION button will illuminate
to show whether looping is on (LED on) or off (LED off).
For output types with multiple options the white LED above the OPTION button will illuminate
momentarily with each press.
3) DIV/MULT QUANTIZE
The DIV/MULT QUANTIZE button will turn quantizing of clock division/multiple settings on or off for
the selected output.
When quantizing is on, the white LED above the DIV/MULT QUANTIZE button will illuminate and the
clock divisions/multiples for the selected output will lock to one of the 12 clock divisions listed in the
vertical column on the front panel labeled DIV.
When quantizing is off, the white LED above the DIV/MULT QUANTIZE button will be off and the
clock division at the selected output will move incrementally.
When quantizing is off, the vertical row of 12 white LEDs will flash at different speeds to show how
far from (slow flash) or close to (fast flash) a particular clock division you are.
4) OFFSET QUANTIZE
The OFFSET QUANTIZE button turns quantizing of phase offset positions on or off for the
selected output.
When quantizing is on, the white LED above the OFFSET QUANTIZE button will illuminate.
When turning the PHASE OFFSET – the phase offset for the selected output will lock to one of the
12 phase offset positions listed in the vertical column on the front panel labeled OFFS.
When quantizing is off, the white LED above the OFFSET QUANTIZE button will be off and the phase
offset at the selected output will move incrementally.
When quantizing is off, the vertical row of 12 white LEDs will flash at different speeds to show how
far from (slow flash) or close to (fast flash) a particular phase offset you are.
5) MUTE SELECTED OUTPUT
Simultaneously clicking both the EDIT and OFFSET QUANTIZE buttons will mute or unmute the
currently selected output.
The blue Edit LED of the currently selected output will flash to show that output has been muted.
© 2016 Abstract Data Ltd.