3onedata TNS5800 Series クイック・インストール・マニュアル
Model III and Model IV
Notice Before Mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【Rack-mounting】
Select the device mounting position and ensure
enough mounting size is reserved.
Adopt bolts to install the mounting lugs in the
device position as figure below.
Place the device in the rack; adopt 4 bolts to fix two
sides mounting lugs in the rack.
Check and confirm the product is firmly installed on
the rack, then mounting ends.
【Disassembling Device】
Device power off.
Unscrew the fixed mounting lug screw on the rack.
Shift out the device from rack, disassembling ends.
Notice before power on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
then plug the power supply plug contact and power on.
Power OFF operation: First, remove the power plug,
then remove the wiring section of terminal block. Please
pay attention to the above operation sequence.
【Power Supply Connection】
Model I and Model II
The Model I and II device of
this
independent
supply systems, P1 and P2,
which support reverse connection protection and power
redundancy backup. Power interface adopts 8-pin 5.08mm
pitch terminal blocks (includes 6-pin power supply), pin
definition are shown as above. Power supply input range:
110VDC (66~156VDC).
Model III and Model IV
The Model III and IV device of this series provide
two independent DC power supply systems, P1
and P2, which support reverse connection
protection and power redundancy backup. The
power supply interface adopts M23 7-Pin pin (male) connector.
Input voltage of power supply: 110VDC The pin definitions of
M23 (male) are shown as follows:
Pin No.
1
2
3
4
Definition
V1+
V1-
V2+
V2-
【Relay Connection】
Model I and Model II
The Model I and II device of
this
5.08mm
blocks and supports 1 relay
series
provide
two
DC
power
5
6
7
R1
GND R2
series
adopts
8-pin
pitch
terminal