- ページ 3

スイッチ 3onedata TNS5800-8GP4GT-2P110のPDF クイック・インストール・マニュアルをオンラインで閲覧またはダウンロードできます。3onedata TNS5800-8GP4GT-2P110 5 ページ。 Layer 3 rack-mounted en50155 industrial ethernet switch

terminal blocks and support 1 relay alarm output, the relay
occupies 2 pins, pin definition is shown in the above figure. R1
and R2 are a group of normally open contacts of the device
alarm relay, which is open in normal no-alarm state and
closed when any alarm information appears. For example,
they are closed when powered off, and send out alarm. The
relay supports the output of DC power supply alarm
information or network abnormality alarm. It can be connected
to alarm light or alarm buzzer or other switching value
collecting devices, which can timely inform operators when
the alarm occurs.
Model III, Model IV, and Model V
The Model III, Model IV, and Model V provide
7-pin M23 interface, pin 5 and 7 are relay pins.
The relay is a group of normally open contacts,
which is open in normal no-alarm state and closed
when any alarm information occurs. For example, they are
closed when powered off, and send out alarm. The device
supports 1 relay alarm information output that can output
network abnormality alarm. It can be connected to alarm light
or alarm buzzer or other switching value collecting devices,
which can timely inform operators when the alarm occurs.
【Console Port Connection】
Provide 1 program debugging port based on
RS232 serial port which can conduct device CLI
command management after connecting to PC.
The interface adopts RJ45 port, the pin definition as follows:
Pin No.
2
3
Definition
TXD
RXD

【Communication Interface Connection】

100M M12 Interface
The Model I and III device provide 10/100Base-T(X)
interfaces, the interface type is M12 D-Coded 4-Pin
slot (female). The definitions of M12 pin are as
follows:
Pin No.
Definition
1
TX+
2
RX+
3
TX-
4
RX-
Gigabit M12 interface
Provide 10/100/1000Base-T(X) interfaces, the
interface type is M12 X-Coded 8-Pinslot (female).
The Model III, Model IV, and Model V support PoE
power supply, single port supports up to 30W PoE power
output, PoE power supply Pin 1 and 2 are positive, 3 and 4
are negative.
The products of this series support two groups of Bypass
functions, and the Bypass ports are shown below.
Model
Model I
Model II
Model III
Model IV
Model V
The pin definitions of M12 are shown as follows:
Pin No.
Definition
1
D0+ (DA+)
5
GND
2
D0- (DA-)
3
D1+ (DB+)
4
D1- (DB-)
5
D3+ (DD+)
Pin Description
Positive send data of 100M
Ethernet
Positive receive data of 100M
Ethernet
Negative send data of 100M
Ethernet
Negative
receive
data
of
100M Ethernet
Bypass
G1-G3, G2-G4
G9-G11, G10-G12
G1-G2, G3-G4
G1-G2, G3-G4
G17-G18, G19-G20
Description
Positive
bi-directional
data
of
Gigabit Ethernet group 1
Negative bi-directional data of
Gigabit Ethernet group 1
Positive
bi-directional
data
of
Gigabit Ethernet group 2
Negative bi-directional data of
Gigabit Ethernet group 2
Positive
bi-directional
data
of
Pin No.
Definition
Description
Gigabit Ethernet group 4
6
D3- (DD-)
Negative bi-directional data of
Gigabit Ethernet group 4
7
D2- (DC-)
Negative bi-directional data of
Gigabit Ethernet group 3
8
D2+ (DC+)
Positive
Gigabit Ethernet group 3
【Checking LED Indicator】
Provide LED indicators to monitor its operating status, which
has simplified the overall troubleshooting process. The
function of each LED is described in the table below:
LED
Indicate
Description
PWR
P1/2
ON
running normally
P1/P2
PWR P1/2 is disconnected and
OFF
running abnormally
ON
Power supply or port link has alarm
ALM
Power supply or port link has no
OFF
alarm
The device is powering on or the
ON
device is abnormal.
The device is powered off or the
RUN
OFF
device is abnormal.
Blinking 1 time per second, system
Blinking
is running normally
Ethernet port has established a
ON
valid network connection
Ethernet port
LINK
Blinking
network status
Ethernet port has not established
OFF
valid network connection
PoE
POE port is powering other PD
ON
devices normally
POE port is not powering other PD
OFF
devices
bi-directional
data
of
is
connected
and
is in an active