ベビーアクセサリー DAN DRYER 659のPDF インストレーション・インストラクションをオンラインで閲覧またはダウンロードできます。DAN DRYER 659 2 ページ。 Safety baby changing station

Read the installation instructions thoroughly before
commencing installation.
The design of the safety baby changing station makes it easy to
mount in even very small rooms. The changing table must be
mounted onto a wall which is suited to carry the weight of the
table as well as a baby – preferably a solid wall !
Where to mount the Baby Changing Station
Determine the ideal place to mount the baby changing table. Keep
in mind that the depth of the changing table is 625 mm in open
position. The distance from the floor to the lower edge of the table
mountings should be approx. 750 mm (see FIG. 1). Doorways,
sinks etc. should of course also be taken into consideration when
choosing where to mount the changing table.
IMPORTANT: Do NOT mount the table in a chlorine-containing
environment!
Marking and drilling holes
To mount the changing table onto brick, gas concrete or the like,
use 10 mm screws and matching universal plastic dowels – e.g.
Fischer fixings type S-12. When mounting the changing table onto
a cavity wall of min. 16 mm (or 2 x 13 mm) plaster board, we
recommend prior mounting of a reinforcement plate of stainless
steel, plywood or the like, onto which the changing table is
subsequently mounted. Attach reinforcement plate to the wall
using a considerable number of special metal cavity fixings,
Fischer part. no. BC 62328 or equivalent (part. no. BC 62315 for
double plate). The changing table itself is also mounted with these
screws and dowels – plus one metal washer per screw hole. For
further details, please refer to the instructions of the dowel
supplier. In places where plaster walls have not yet been finished,
we suggest mounting a 16 mm plywood board on the inside of the
plaster wall, rendering the need for a reinforcement plate on the
outside unnecessary. Mark and drill holes as indicated on FIG. 1.
The top holes for the table mountings should be drilled into solid
brick - not into a joint.
Mounting the Baby Changing Station
➊ Disassemble the cover plates of the table mountings by
removing the 6 screws
(3 on each) with a Torx screwdriver no. 20.
➋ Mount the table onto the wall, making sure that it is completely
level.
➌ The baby change unit is factory pre-adjusted to easily close
when given a slight push from open position.
➍ Check that the changing table is mounted solidly onto the wall.
➎ Check that the shock absorbers can pass freely when opening
and closing the table.
➏ Reassemble the cover plates onto the mountings.
Fig. 1
The dimensions stated are based on a
work height of approx. 950 mm.
IMPORTANT: Be sure to drill the holes for the mountings exactly
vertically underneath each other, or the pneumatic shock
absorbers inside the mountings may break