- ページ 3

ネットワーク・ルーター 3onedata IES6312-8GP4GF-2P24-120WのPDF クイック・インストール・マニュアルをオンラインで閲覧またはダウンロードできます。3onedata IES6312-8GP4GF-2P24-120W 4 ページ。 Managed industrial poe/non-poe ethernet switch

3onedata IES6312-8GP4GF-2P24-120W クイック・インストール・マニュアル
information occurs. Such as: it's closed when power off, and
send out alarm. This series switches support 1 channel relay
alarm information output, support DC power alarm information
or network abnormal alarm output, it can be connected to
alerting lamp, alarm buzzer, or other switching value collecting
devices to warn operators timely when alarm information
occurs.
【DIP Switch Setting】
Provide 4-bits DIP switch for function setting, where
"ON" is enable valid terminal. DIP switch define as
follows:
DIP
Definition
Operation
1
Restore
When it is set to ON, the device
factory setting
will reboot and restore to factory
setting automatically. Then pull
it back.
2
Reserved
-
3
Reserved
-
4
Reserved
-
【Console Port Connection】
The device provides 1 program debugging port
based on RS232 serial port. The interface
adopts RJ45 port, and can conduct device CLI
command line management after connecting to PC.
PIN
2
3
Definition
TXD
RXD
【Checking LED Indicator】
This device provides LED indicators to monitor device's
operating state, which has simplified the troubleshooting
process comprehensively. The status of each LED is
described in the table below:
LED
Status
Description
The device is powered on or the
ON
device is abnormal.
RUN
The device is powered off or the
OFF
device is abnormal.
Blinking
Blink 1 time/s, the device runs
ON
ALM
OFF
ON
P1/P2/PWR
OFF
ON
Link
Blinking
G1-G12
OFF
ON
POE G1-G8
OFF
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device's configuration interface via IE
browser is shown as below:
5
Step 3
Configure the IP addresses of computer and the
GND
device to the same network segment, and the
network between them can be mutually accessed.
Step 4
Enter device's IP address in the address bar of the
computer browser.
Step 5
Enter device's username and password in the login
window as shown below.
normally
DC Power supply, port failure
alarm
Relay alarm is turned off or has
no alarm
Power supply P1/P2/PWR is
connected and running normally
Power supply P1/P2/PWR is
disconnected
and
running
abnormally
Ethernet port has established
valid network connection
Ethernet port is in active status
Ethernet port has not established
valid network connection
PD device is powered over PoE
port normally
PD device is not powered over
PoE or not connected to PoE
Step 6
Click "OK" button to login to the WEB interface of
the device.
Note:
The default IP address of the device is "192.168.1.254".
The default username and password of the device is
"admin".
If the username or password is lost, user can restore it to
factory settings via device DIP switch or management
software; all modified configurations will be cleared
after restoring to factory settings, so please backup
configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【Specification】
Panel
Gigabit PoE port
10/100/1000Base-T(X), RJ45,
automatic flow rate control,
full/half
MDI/MDI-X autotunning; PoE
power supply pins: V+, V+, V-,
V-. Output power is 30W
duplex
mode,