INTENDED USE OF PRODUCT
The brass 522 series and the stainless steel 523 Series autoswitch system is intended for use in high
purity, non-corrosive applications. Please note the safety information shown in the later sections.
USER RESPONSIBILITY
The User of this equipment should follow all labeling, installation and operation instructions when
using this equipment. It is recommended that the user review all safety precautions listed in the safety
section of this manual .
Know the properties and special handling requirements of the gas being used. Many gases are
dangerous (flammable, toxic, corrosive , etc.) Consult with the cylinder distributor for the proper
use of the cylinders and any restrictions in their use. This equipment must be checked periodically.
Improperly working equipment should not be used. Broken, worn, distorted, contaminated, or missing
components should be replaced by a trained technician immediately.
CUSTOMER ASSISTANCE
In the event of equipment failure, call the CONCOA Customer Assistance Line: 1-800-225-0473.
Please be prepared to provide the model number and serial number of the equipment involved, in
addition to some details regarding its application. This would include inlet and outlet pressures, flow
rate, environmental conditions, and gas service.
SAFETY
Carefully read and comply with these instructions before installing or operating any high pressure gas
manifold. These manifolds are designed, manufactured, and tested to conform to industry standards
for safety for high pressure gas manifolds for maximum inlet pressure of 3000 pounds per square inch
(200 bar), working pressure.
Always observe the following safety practices:
√
Store cylinders with valve caps screwed on, and cylinders chained to a supporting wall or
column.
√
Handle cylinders carefully and only with valve caps screwed on. The cap will prevent the
cylinder valve from breaking off at the top of the cylinder if the cylinder is accidentally dropped
or falls over. The cap also protects the cylinder valve from damage to screw threads, which
could cause leaky connections.
√
Due to the highly combustible nature of hydrogen, methane, ethylene and fuel gases, all
manifolds used with this gas are provided with flashback arrestors to stop any burning gas in
the pipeline from getting back to the manifold or cylinders. Flashback arrestors are either water
filled or dry check valve type. Gas flowing from the regulators on the manifold flows through the
flashback arrestor to the pipeline. Also, arrestors on hoses are required for acetylene service.
√
Keep all cylinders away from any source of high temperature (not over 120° F, 50° C) or
possible fire hazards. High-pressure gas contained in a closed cylinder becomes increasingly
dangerous when exposed to high temperature because pressure increases and the strength
of the cylinder decreases.
√
No smoking should be permitted near oxygen, nitrous oxide, flammable gases and flammable
mixtures and in area where cylinders are stored.