- ページ 5
セントラル・バキューム・システム AirVac AV2500のPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。AirVac AV2500 6 ページ。 Airvac av2500; av5500 central vacuum system
Assembling the Deluxe Electric System
1. Snap the two interlocking wands
together.
2. Push cord plug up as far as it will go
into plug holder, then press into plug
holder until firmly seated.
3. Press cord into clip.
4. Push downward until wand lock button
snaps into place.
5. Insert SUPERHOSE handle into
wands.
6. Plug electric brush cord into hose
handle.
WARNING
ELECTRICAL SHOCK HAZARD
Do not plug into electrical supply until
assembly is complete. Failure to do so
could result in electrical shock or injury.
Troubleshooting
1. No Power:
Check circuit breaker on unit and house power panel breaker to see if they have
tripped. If they have tripped, then reset. If they trip again, call your local M & S
Systems distributor for service.
2. Low Suction:
Check suction at utility inlet on the power unit.
Check for blockage in hose.
Check for blockage in pipe by using a plumber's snake to free any obstruction.
Check for air leaks at inlet valves not in use. A missing or damaged gasket
could cause air leaks.
Check the 2.75" flock filter located in the screen below the motor plate behind
the filter. If blocked or clogged, this can cause low suction.
If you encounter any problems with your equipment, verify the operation against
the information contained in this booklet. If, after checking your system you are
unable to determine the cause of the problem, contact your local dealer for
assistance or our technical support department at (800) 366-9422. Be sure to
have the exact model number, serial number and the nature of the problem
ready. If possible, CALL FROM THE SITE. We cannot effectively troubleshoot
your system if you are not calling from the location where the equipment is
installed or used.