- ページ 14
送信機 Anywave PA-U2D-C-FAのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Anywave PA-U2D-C-FA 20 ページ。
indicates the TX is ON. When it is RED, it indicates the TX is OFF.
FWD: the Forward Power Meter. Touching the white display box of FWD will toggle its display
units between "dBm" and "W".
REFL: the Reflected Power Meter. Touching the white display box of REFL will toggle its
display units between "dBm" and "W".
VSWR: the Voltage Standing Wave Ratio.
Status Bar: During normal operation, the default status is "RUNNING OK". If there is an alarm, the
alarm will show up in the Status Bar of each screen.
Block Diagram: Press the "Exc A/B" graphic to navigate to the Dual Exciters Switching screen
(shown below). This screen shows which exciter is currently on-air (highlighted in GREEN) and
allows the user to manually change the on-air exciter.
3.2.2. A/B Exciter Icon Screen
Dual Exciters - Switching Screen: Pressing the "Exc A/B" icon will bring you to the Dual Exciters
Switching Screen, a shown below.
Manual Exciter Switchover: As shown above, Exciter A's status is in "GREEN", indicating that Exciter A
is the current on-air exciter, while Exciter B is standby. Pressing the "Exciter A" or "Exciter B" button on
this screen will cause a manual switchover between exciters if the PA is "linked" to both exciters. (Note: In
a dual exciter configuration, both exciters are on at the same time, producing an RF output signal a the
same time, and the PA is considered "linked" with an exciter when the PA detects an RF output present
from the exciter as monitored).
Auto Exciter Switchover: In a Dual Drive configuration, the PA is set to automatically switch to the
standby exciter in the event a problem occurs with the on-air exciter. The PA will not automatically switch
back to the original Exciter as long as the standby Exciter is operating properly. However, the PA will
ACT-PA-U2D-USR-DOC-V2.2, 09/25/2019
PA-U2D-C-FA User Manual
Page 14 of 20