バッテリーチャージャー Concorde BC-8000のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Concorde BC-8000 14 ページ。
Concorde BC-8000 にも: フィールド校正手順 (11 ページ)

BC-8000 Field Calibration Procedure
CF-1_FIELDCAL_BC8000 Revised 10/16/2019
INTRODUCTION:
The BC-8000 Battery Capacity Tester and Charger (P/N 4168) performs
C1-Ahr capacity testing on 12 and 24-volt lead-acid, Nickel Cadmium, and
Lithium Ion aviation batteries. Capacity testing amperage resolution is
0.1A /step for batteries with C1 ratings of 0.5Ahr to 55Ahr. Using the BC
Report application, the battery technician can retrieve capacity test data
from the BC-8000 to create a printable report that includes test settings,
test results, time and date of test, and a battery voltage graph. The BC-
8000 is universally line powered 100 to 230VAC 50 to 60hz 1 phase. The
recommended calibration interval is 1 year.
The BC-8000 charging amperage resolution is 0.01 amps from 0.050 to
2.50 amps and 0.1 amp from 2.6 to 25 amps. The BC-8000 battery
charger voltage range is 3.0V to 36.2V. When operating at 3.0V the
maximum amperage is 2 amps. The BC-8000 offers single or two step
charging routines and charges constant voltage or constant current.
SCOPE:
This document provides instructions on how to perform the annual
calibration of the BC-8000 using the CF-1 (P/N 4170). The BC-8000
calibration is broken down into the following categories:
Verify capacity test timing accuracy.
Calibrate EPV Cutoff at 10.00 Volts.
Calibrate EPV Cutoff at 20.00 Volts.
Calibrate capacity test load current points.
Calibrate the BC-8000 charger output voltage points.
Calibrate the BC-8000 charger output current points.
Optional Calibrate the Real Time Clock (RTC) chip. The clock is
calibrated at the factory. Re-adjustment can be done if the time
keeping accuracy is unacceptable. The date and time are set to the
current PC time by the BC Report application every time test results
are transferred from the BC-8000 to the BC Report application.
Page 1
(Using the CF-1)