3 Auto Switching - Setup and Operation

Auto mode: Set the switch controller to Remote mode from its front panel
1)
Log into the web interface on both amplifiers, and change
their control mode from LOCAL to REMOTE (note: the coaxial
switching only works when both amplifiers are in REMOTE mode). The
RF-CTRL-MODE setting is shown in Figure 2. When switched to
REMOTE mode, the amplifiers' front panel RF On/Off buttons will be
inactive.
2)
Connect all cables/wires as shown in Figure 1, and then turn
on the exciters, amplifiers, coaxial switch and switch controller.
If any power amplifier has a proper output power that is higher than a
pre-set minimum level, then the amplifier can be determined as
VALID. If both PAs are valid, then amplifier A will be selected as the
default PA (Note: The PA connected to REMOTE 1 on the back panel
of the switch controller is recognized the amplifier A, and the PA
connected to REMOTE 2 is recognized as amplifier B).
If there is a problem with the serial port communication between the
PAs and the controller, it will show error on STATUS->
LPTV_A_UART or LPTV_B_UART on the web page as shown in
figure 3.
RF-SWITCH-USR-DOC-V2.0, 1/6/2017
Figure 2
RF Switch Controller User Manual