5) ELECTRICAL CONNECTIONS

IMPORTANT: the appliance must be
installed following the manufacturer's
instructions. The manufacturer will not be
liable for injury to persons or animals or
property damage caused by an incorrect
installation.
The electrical connection must be made in
conformity with current rules and regulations.
Before making a connection, check that:
- the capacity and outlets of the electrical
installation are suitable for the maximum power
output of the appliance (see the information label
attached on the underside of the housing).
- The outlet or installation is provided with a good
earth connection according to standards and
provisions currently in force. All responsibility is
declined for failure to comply with these
provisions.
- If a power cord is not supplied with the appliance,
connect a cable with a suitable section to the
terminal board (see table in paragraph 6)
keeping the earth wire longer than the lead
wires, following the diagram in fig. 9.
When connection to the power circuit is made
through an outlet:
- apply to power cable "C", if not provided, a
standard plug suitable for the load indicated on
the information label. Connect the wires as in the
diagram in fig. 9 taking care to observe the
responses listed below:
letter L (phase) = brown cable;
letter N (neutral) = blue cable;
symbol
(earth) = yellow-green cable.
- The power cord must be placed in a way that it
does not reach an excess temperature of 90 °C
in any position.
- To connect, do not use adaptors or switches as
they may cause false contacts resulting in
dangerous overheating.
- The outlet must be accessible after the built-in.
When connection is made directly to the power
circuit:
- place a switch between the appliance and the
circuit of an appropriate size for the load of the
appliance and with a minimum aperture between
contacts of 3 mm.
- Remember that the earth cable must not be
broken by the switch.
- The electrical connection may also be protected
by a high sensitivity differential switch.
It is strongly recommended that the yellow-green
earth cable provided be connected to a good earth
INSTALLATION
installation.
Before performing any service on the electrical
part of the appliance, it must absolutely be
disconnected from the electrical network.
WARNINGS:
all our products are conform with the European
Norms and relative amendments. The product
is therefore conform with the requirements of
the European Directives
in force relating to:
- compatibility electromagnetic (EMC);
- electrical security (LVD);
- restriction of use of certain hazardous
substances (RoHS);
- EcoDesign (ERP).
If the installation requires modifications to
the home's electrical system or if the
socket is incompatible with the appliance's
plug, have changes or replacements
performed by professionally-qualified
person. In particular, this person must also
make sure that the section of the wires of
the socket is suitable for the power
absorbed by the appliance.
In case of failure or cut in the cable,
please move away from the cable
and do not touch it. Moreover the
device must be unplugged and not
switched on. Call the nearest
authorized service center to fix the
problem.
10