[About Single Unit Simplified Replacement]
During replacement of a slave unit, this function enables automatic settings of
address and parameters of the existing slave unit into a new slave unit. (After
replacement of the slave unit, address and parameter setting procedure using the
address writer is not required.)
■Step 1  Turn OFF the 24V DC power supply for the master unit.
■Step 2  Disconnect a slave unit to be replaced.
ASLINK
master unit
■Step 3  Connect a new slave unit.
NEW
ASLINK
master unit
■Step 4  Turn ON the 24V DC power supply to the master unit.
CAUTION
- It is necessary that both the master unit and slave unit should be compatible
with the single unit simplified replacement function.
- Before disconnection and connection of the slave unit, be sure to turn OFF the
power supply.
- For compatibility of a slave unit with the single unit simplified replacement
function, see the lot No. and the manual for the slave unit.
- When a slave unit of a new function version is replaced with that of an old
function version, the single unit simplified replacement function cannot be
used.
- Operation is enabled in the case where the model of the slave unit before
replacement is the same as that after replacement.
- If the model of the slave unit before replacement is different from that after
replacement, a model mismatching error occurs, disabling address and
parameter settings.
- Operation is enabled in the case where the address of the slave unit for
replacement is the factory-set address (bit address 511).
- Several slave units cannot be simultaneously replaced. For replacement of
several slave units, conduct the replacement procedure for each unit one by
one.
- For a slave unit incompatible with the single unit simplified replacement
function, set an address and parameters by using the address writer as in the
conventional manner.
- For details of the single unit simplified replacement function (limitations,
conditions, etc.), refer to the manual for the master unit.
■Identification of function version
Function version information is given on the lot label.
* The design and contents of the lot label may vary depending on the product
model and lot No.
Function version:
When an equipment parameter
is changed due to functional
upgrading, etc., the function
version will be updated (for
example: A→B→C).
When a slave unit of a new
function version is replaced
with that of an old function
version, the single unit
simplified replacement function
cannot be used.
-B284SB0*1K**P30 2/16-
[Functions]
Model
ASLINKSENSOR 2-wire type (non-isolated)
Indication mode
Gage pressure
Pipe connection
M5 female thread
bore diameter
Bit transmission
Word transmission*
Single unit simplified replacement*
Remote address change*
Alarm bit
Threshold setting (upper limit, lower limit)
Functions
Operation mode setting (hysteresis mode, window comparator mode)
Input logic selection
Input response time setting
Alarm setting (upper limit, lower limit)
Alarm judgment time setting
Zero correction
Bit address setting
Address
Word address setting
*1 It depends on lot No. whether this function is available or not.
*2 This unit can be used in connection to the AnyWireASLINK system for word transmission.
Note that this unit cannot handle word data by setting a word address.
*3 To use these functions, a master unit compatible with each function is required.
For details, refer to this manual together with the manual for the master unit.
■Detecting functions (Status details)
Slave unit voltage drop
Sensing level drop
I/O cable disconnection
Functions
I/O short-circuit
I/O power supply drop
[Function Compatibility by Lot No.]
This unit has undergone addition of functions and change of specifications
according to version upgrading. Available functions and specifications of the unit
vary depending on lot No.
Function/specification
Remote address change
Single unit simplified replacement
Word transmission*
4
LED indication for single unit
simplified replacement function*
5
*4 This unit can be used in connection to the AnyWireASLINK system for word transmission.
Note that this unit cannot handle word data by setting a word address.
*5 In the case where a lot No. indicates year and month digits of "15I" or later, the single unit
simplified replacement function works even if the lot number does not support the LED
indication for the single unit simplified replacement function.
(When the master unit executes the single unit simplified replacement function,
addresses/parameters will be written, if specified conditions are satisfied.)
■How to check
Lot No. is indicated on the lot label.
Example:
Lot No. 19ECBNB
Year and month
*
1
2
*
1
3
*
1
3
×
×
×
Lot No.
Available with lot No. that indicates year and
month digits of "15I" or later.
Available with S/W version "B" or later version
(If lot No. is indicated in 3 digits (year and
month only), these functions are not available.)
Side surface of
this unit
S/W version
×