[Parameters (sequel)]
■Parameters of representative models
Type
AnyWireASLINK
Mapping terminal
[Reading of parameters]
Check that power (in the case of 2-wire type, transmission signal) is supplied to the reading target unit.
■Parameter reading operation
How to operate
1
Turn ON the POWER switch.
2
Press the SELECT switch.
Press the SELECT switch several
3
times to light the READ display.
4
Press the SET switch.
Press the UP switch to display
the P number of the parameter type
5
to be read from the target terminal.
Point the light emitting and
receiving part (Yellow frame) at
6
the unit to press the SET switch.
7
In the case of failure in reading
Readjust the light emitting and
8
receiving part and
press the SET switch again.
- Clear the Err display.
- Switch the mode to another mode.
9
Press the CLEAR switch.
If reading parameters from
10
another unit, return to Operation No.6
to repeat the operations.
If returning to the address setting mode,
11
press the DOWN switch once.
After using ARW-03, keep the POWER switch
pressed to turn OFF the power.
Model
01
02
B232SB-MX100-STP
B232SB-SX100-STP
03
Details of parameter
0, 1, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
Before shipment: 10
0 (Collective setting of sensitivity), 1 (Individual setting of sensitivity)
Before shipment: 0
0 (with error sensor unit monitoring function)
1 (without error sensor unit monitoring function)
Before shipment: 0
READ (green)
Example)
Example)
Example)
-ARW03 13/17-
Display
After approximately
2 seconds, "SELECt" flashes.
Flashing
The reading mode is
determined.
Select parameter 1.
During the reading operation
Parameter value read
Err display
During the reading operation
Parameter value read
Return to the reading
mode display
Change to the Ad display.
READ must be lighted.
Sensitivity
Sensitivity setting mode
of B232SB-SX100-STP
Error sensor unit
monitoring
function
Light emitting and
receiving part
(yellow frame)