- ページ 15

アクセサリー Duerkopp Adler 911のPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Duerkopp Adler 911 20 ページ。 Laser lamp
Duerkopp Adler 911 にも: 取付説明書 (16 ページ), 取付説明書 (8 ページ), 取付説明書 (16 ページ)

Duerkopp Adler 911 取付説明書
Fitting Instruction for Remaining Thread Monitor
2.3 Pre-assembling, connecting and attaching the control
Ausgabe/Edition:
Änderungsindex
03.2011
Rev. index: 00.0
Anbauanleitung Restfadenwächter
Teilesatz 0911 597754
Kit 0911 597754
Insert the spacers 1 (4x) into the bores of the residual thread
monitor carrier and attach the PCB 2.
1
Connect the cables onto the residual thread monitor PCB:
Plug connector X623 (from the cable harness or cable 9870
911017) to position 3; plug connector X621 of the light
barrier cable to position 4.
Attach the cables with the cable clips 5 to the residual
thread monitor carrier.
Screw the residual thread monitor carrier with PCB onto
the right console by using two M3 screws 6.
2
3
4
5
6
Printed in Germany
Teile-Nr./ Part-No.:
0791 911703
2
Blatt:
von
Sheet: 15 from 20