- ページ 12
モニター Duerkopp Adler 911のPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Duerkopp Adler 911 20 ページ。 Laser lamp
Duerkopp Adler 911 にも: 取付説明書 (16 ページ), 取付説明書 (8 ページ), 取付説明書 (16 ページ)
Fitting Instruction for Remaining Thread Monitor
2
Mounting the bobbin thread monitor (RFW)
2.1
Mounting the light barrier
Ausgabe/Edition:
Änderungsindex
03.2011
Rev. index: 00.0
Anbauanleitung Restfadenwächter
Teilesatz 0911 597754
Kit 0911 597754
–
Attach the pre-assembled carrier 2 by using screw 1.
–
Position the light barrier so that its light beam points through
the slit on the bobbin case onto the reflecting surface on the
bobbin and back to the light barrier.
Note:
In general the front edge of the light barrier device has to come
parallel with the front edge of the carrier 2.
–
Connect the hose 3 for the compressed air.
2
1
Printed in Germany
Teile-Nr./ Part-No.:
0791 911703
3
Blatt:
von
Sheet: 12 from 20