- ページ 14

ウォーターヒーター Anzzi ENVO WH-AZ006-M1のPDF インストール&オペレーションマニュアルをオンラインで閲覧またはダウンロードできます。Anzzi ENVO WH-AZ006-M1 16 ページ。 Electric instant water heater

Anzzi ENVO WH-AZ006-M1 インストール&オペレーションマニュアル

OPERATION INSTRUCTIONS

CAUTION: Wait until water is fully flowing through the heater before turning on
the breaker.
1. Allow water to flow through the water heater unit. Allow the water to flow continuously to
flush out any debris as well as purge the pipes of any air.
2. Turn on the breaker to power the water heater. An audible beep will be heard and the LED
display will light up for 2 seconds.
3. After power the water heater the unit will turn ON once the minimum water flow runs through
the heater. The min water flow to activate the unit is 0.4GPM (1.5L/min).
4. Stopping the flow of water will shut down the water heater. It is not necessary to turn the
breaker OFF.
5. Press
to adjust the water's temperature between 86-131 °F (30-55 °C). The default
temperature is 105 °F (41 °C).
6. Continuously press
7. Press
once to switch between Fahrenheit and Celsius.
8. If the unit is installed upside down press and hold
display 180 °.
9. There is an over-temperature protection system for this unit. When the temperature reaches
149 ° F (65 ° C) the system will automatically start to decrease the temperature until it's back
to a safe level. Only then will you be able to increase the temperature again.
10. There is electric leakage detection function, while there is a leakage, the appliance will stop
working automatically.
11. Please check hot water with hand before you taking a shower.
If the unit will not be used during the winter completely drain out the water to prevent freezing.
Periodically clean the water heaters inlet strainer, the faucet's aerator, and the shower's head
to ensure free flow of water.
CLEANING & MANTENANCE
ATTENTION
Do not attempt to repair the water heater unit yourself. Please contact a certified professional
or call our customer support for assistance. It is important to shut off all power to the water heater
directly at the fuse or breaker. Failure to do so could cause permanent damage to the water
heater and void the product warranty.
Before performing any maintenance make sure to take precaution and prevent exposure to the
potentially hot water. The water may be hot enough to present a serious scalding hazard. The
water should be safely drained to prevent any injury or property damage.
It is recommended to regularly maintenance the water heater. Proper maintenance will help
lead to a long running, trouble free water heater.
Periodically remove scale and dirt that may build up at the faucet aerator.
PG.10
to cycle between 100 °F – 107 °F – 131 °F (38 °C – 42 °C – 55 °C).
for 3 seconds to reorient the LED