- ページ 7

水システム Addie Water Systems TIG56SXT-SのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Addie Water Systems TIG56SXT-S 19 ページ。 Chemical free iron & sulfur reduction

IRON GENIE MASTER PROGRAMMING GUIDE
Press the Up or Down Arrow Buttons to enter the Time of Day
Programming Mode, Set the Time of Day Display to 12:01 P.M.
Press the Extra Cycle Button once to exit the Time of Day Programming
Mode.
With the Time of Day Display set to 12:01 P.M., Push and hold the Up
and Down Arrow Buttons for 7 seconds.
Press the Extra Cycle Button once to advance to next parameter.
1.
DF - GAL - US Gallon Display Format
2.
VT - dF1b – Down flow, Single Backwash
3.
CT - tc - Time Clock Control
4.
NT - 1 - Single Tank System
5.
DO - 3 - Day Override
6.
RT - 12:30 A.M. - Time of Regeneration
7.
BW - 10 - 10 Minute Backwash
8.
BD - 40 - 40 Minute Air Recharge (80 minutes for ECM model)
9.
RR - OFF - Rapid Rinse is Turned Off
10.
Exit Master Programming and Return Valve to Service Display