コントローラー Abtus SKP-15iのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Abtus SKP-15i 12 ページ。 Smart controller
2.2.2 Default icons
In the event that the application requires the Smart Controller to show a different set
of icons when powered on, create another set of 15 icons and name them boot_1.jpg,
boot_2.jpg and etc.
This will allow the panel to show these boot icons automatically when powered on.
2.3 Saving icons into the Smart Controller
Press and hold the 3 buttons in the middle (button 3 + 8 +13) and plug the USB cable
into the PC.
Once connected, the Smart Controller will show up as a device along with other devices
and drives that's currently on the PC.
Locate the device and drop the previously prepared icons files into the Smart Controller.
2.4 Configuring the Smart Controller
To assign a hex command to a specific key, connect the RS-232 cable to the PC. (Use
a RS-232 to USB adaptor if required)
Use any scripting software and establish connection with the Smart Controller.
Send a command to the Smart Controller using the following format:
Protocol Tables:
Edit Button commands (Button state Protocol)
Field
StartCode
Value (hex)
55
Description
Fixed
Note: Under "Data 1", "P" denotes Press and "R" denotes Release. "Data 3" denotes the command code required to control the connected equipment
Show Gallery Image on Button
Field
StartCode
Value (hex)
55
Description
Fixed
Show Gallery on Multiple Button
Field
StartCode
Value (hex)
55
SYSTEM OPERATIONS
Length
CRC16
AA
...
...
FF
low
high
byte
byte
Skip CRC check
Length
CRC16
AA
...
...
FF
low
high
byte
byte
Skip CRC check
*Specifications are subject to changes without notice.
Length
CRC16
AA
...
...
FF
AT Command
Data 1
FF
53 43 4D 44
...
P or R
(Button
SCMD
state)
AT Command
Data 1
FF
53 47 49 42
...
Button
SGIB
Index
AT Command
Data 1
FF
53 47 4D 42
...
Table 1
Data 2
Data 3
End Code
...
...
0D
0A
Button
Fixed
index
command
Table 2
Data 2
Data 3
End Code
...
...
0D
0A
Gallery Index
Fixed
Table 3
Data 2
Data 3
End Code
...
...
0D
0A
9