掃除機 Dultmeier Sales DU V450WO-9RのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Dultmeier Sales DU V450WO-9R 7 ページ。 Vacuum tank unit

Parts Identification

1 - Primary Shutoff - When the tank (2) gets full of
waste, the primary trap (1) will shut off vacuum flow.
1A - Access Lid - Access port to primary trap for
maintenance and tank inspection.
2A - Tank Drain - Drain waste from tank. To assist in
drainage follow these steps:
1. Remove safety cap (2B)
2. Hook up discharge hose
3. Open tank drain (2A)
4. Set pump vacuum/pressure changeover
valve (5B) to neutral (center) position.
5. Allow tank to drain
6. For quicker off loading start motor and turn
vacuum/psi changeover valve (5B) on pump
to #1 - pressure
3 - Secondary Shutoff - When the tank (2) is full of
waste and the primary shutoff (1) fails the secondary
shutoff will begin to fill. STOP USE IMMEDIATELY.
Drain tank (2) and secondary shutoff (3A), then
service primary shutoff (1).
3A - Waste Drain - Use to drain secondary shutoff (3).
4 - Oil Trap Muffler - Catches used oil and reduces
exhaust noise. It is recommended that the oil trap
muffler is drained (4A) at the same time the waste
tank (2) is drained. Properly collect, contain, and
dispose of used oil.
4A - Oil Drain - Use to drain oil trap muffler (4).
2
4A
1A
1
3
4
3A
7
5
2A
2B
5 - Vacuum Pump - It is vital to the longevity of the
pump to read and understand the pump manual.
Always maintain proper oil levels and
IMPORTANT
run pump at proper RPM.
5A - Oil dipstick for Lubrication Oil Tank - Check
and fill oil daily and each time the unit is being used.
Always use vacuum pump oil. See List
IMPORTANT
of Recommended Oils in pump manual.
5B - Vacuum/Pressure Changeover Valve - Switches
from #2 Vacuum to #1 Pressure or neutral (in
between).
5C - Oiler Adjustment - Adjust oiler to 1 drip every
other second. See Lubrication Checking in pump
manual.
6 - Vacuum Relief Valve - Vacuum relief valve will
open when vacuum in tank (2) exceeds 25 HG. This is
factory set during testing and should not need further
adjustment.
6A - Pressure Relief Valve - Pressure relief valve will
exhaust pressure above 5 psi in tank (2).
6B - Vacuum/Pressure Gauge - Use to read vacuum
or pressure of unit.
7 - Honda Engine - Quick start guide on page D is
provided for easy reference. Read and understand
Honda Owner's Manual for further detail.
6
5A
Parts Identification | C
5B
5C
6B
6A