- ページ 5

サーモスタット Danfoss Basic Plus2のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Danfoss Basic Plus2 8 ページ。 Room thermostats floor heating

Danfoss Basic Plus2 ユーザーマニュアル
User Guide
8

Child Safety Lock

Press "M" and hold. Press ">" within 6 seconds to lock all buttons.
Operate again to exit the child safety lock.
9

Set Control Parameters

Press "M" button for 6 seconds to enter the parameter setting
mode. Press "M" for parameter selection and set the parameter
range via "<" or ">". Complete all adjustments. To exit WT-P/PR,
press
, which is available for this purpose (automatic exit after
30 seconds with no operation). To exit WT-D/DR, wait for automat-
ic exit (30 seconds). The upper digits indicate the parameter num-
ber. The digits indicate the set value as follows.
No. Parameter set-
Settings range
tings
P01 Working mode
01: Manual ; 02: APT
P02 Temperature con-
01: Only room temp.;
trol mode
02: Room and floor
temp.; 03: Only floor
temp.
10
Error Messages
Error messages are displayed as follows:
▪ E1 = room sensor failure
▪ E2 = floor sensor failure
▪ EE = EEPROM failure
▪ Lo = temperature lower than 0 °C
▪ HI = temperature higher than 50 °C
All relay output will be turned off in all cases.
Danfoss Heating Solutions
2
Basic Plus
Room Thermostats Floor Heating
No. Parameter set-
P03 High room temp.
P04 Low room temp.
P05 Floor temp. limita-
P06 Floor temp. limita-
P07 High floor temp.
P08 Low floor temp.
P09 Frost protection
Factory default
P10 Frost protection
WT-
WT-
D/DR
P/PR
P11 Timer display op-
NA
02
01
01
P12 Room temp. dis-
P03 to P08 appear on relevant temperature control mode.
Settings range
tings
5-35 °C (only for 01and
limit
02 in P02)
5-35 °C (only for 01and
limit
02 in P02)
01: High temp. limita-
tion mode
tion: 02: Low temp. lim-
itation (only for 02 in
P02)
20-45 °C (only for 02 in
tion setpoint
P02)
20-45 °C (only for 03 in
limit
P02)
20-45 °C (only for 03 in
limit
P02)
01: Enable; 02: Disable
5-17 °C
setpoint
01: 24 h; 02: 12 h
tion
01: No display current
play option at
temp.; 02: Display cur-
shutdown
rent temp.
VUCUA102
Factory default
WT-
WT-
D/DR
P/PR
30 °C
30 °C
5 °C
5 °C
01
01
35 °C
35 °C
35 °C
35 °C
20 °C
20 °C
01
01
5 °C
5 °C
NA
01
01
01
5