- ページ 3

サーモスタット Danfoss TP5001 seriesのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Danfoss TP5001 series 4 ページ。 Programmable room thermostat
Danfoss TP5001 series にも: 簡単設定マニュアル (2 ページ)

Danfoss TP5001 series ユーザーマニュアル
User Guide
7
Frost Protection Temperature
• You can switch the thermostat OFF (Standby) by alternately pressing
stat is set to a Frost Protection temperature setting and will switch On only if the measured temperature falls
below this temperature (5 °C by default).
• The frost protect icon and current temperature will be displayed.
8
Advanced Programmable Timer
The Advanced Programmable Timer mode enables the setting of a timer-controlled program for automatic
comfort temperature, and an energy-saving lower setback temperature if standard room comfort temperature is
not required.
Example below for 5/2 day setup, 4 Temperature settings.
The function consists of 2 programs:
P1 with 4 events in 5 days (Mon. Tue. Wed. Thu. Fri.)
P1: Press
for 3 secs to display Mo. Tu. We. Th. Fr.
P1, Event 1:
1. Use < or > to select the start hour.
2. Press
to accept the setting.
3. Use < or > to set the minute.
4. Press
to accept the setting.
5. Use < or > to select the temperature.
6. Press
to accept the setting.
P1, Event 2-4:
Repeat the Event 1 procedure for programming
Event 2-4.
If schedule working mode is set to 24hr, only P1 program will be available, see parameter P01. Mo. to Su. will be
set together with the same times and temperatures.
The thermostat will continue the 4-event program based on the present time and day.
To set and change the room temperature temporarily:
1. Press < or > at any time to change the desired temperature value. SET is shown in the display.
2. When releasing the < or >, the display returns to showing the actual temperature. This temperature change is
only temporary and will be maintained only until the next programmed setting!
A default program provides timer control if the customer does not create own programs:
Days
Event 1
Start time
Mo. - Fr.
6:30
Sa. - Su.
7:30
* 24hr mode default program same as Mo. - Fr. above.
09/2020
TP5001 Programmable Room Thermostats
Event 2
Temp.
Start time
20° C
8:30
20° C
9:30
. In OFF (Standby) mode, the thermo-
P2 with 4 events in 2 days (Sat. Sun.).
P2: Sa. Su. are now shown in the display.
P2, Event 1:
1. Use < or > to select the start hour.
2. Press
to accept the setting.
3. Use < or > to set the minute.
4. Press
to accept the setting.
5. Use < or > to select the temperature.
6. Press
to accept the setting.
P2, Event 2-4:
Repeat the Event 1 procedure for programming
Event 2-4.
Event 3
Temp.
Start time
15° C
16:30
15° C
16:30
VUSUF102
Event 4
Temp.
Start time
20° C
22:30
20° C
22:30
Danfoss Heating
Temp.
15° C
15° C
3