System image
Dew point sensor
Pilot valve
cooling circuit
Cooling circuit
Sensor, cooling tank
Sensor, cooling circuit
Circulation pump
cooling circuit
Transmitter, cooling tank
A strap-on temperature detector is connected on the cooling tank at about a third of the tank's height.
Transmitter, cooling circuit
A strap-on temperature detector is connected on the supply line of the cooling circuit, after the circulation pump.
Transmitter, cooling tank outlet
A strap-on temperature detector is connected on the return line of the cooling tank.
Transmitter, coolant cooler
A strap-on temperature detector is connected on the return line from the coolant cooler, as close to the cooler as pos-
sible .
12 – Danfoss
Reversing valve
surplus heat
Sensor, cooling tank outlet
Cooling tank
Cooling agent circuit
VMILF102
Heat circuit
cooling module
DHP-R Eco
Modular cable
Reversing valve, cooling tank
Reversing valve
cooling agent return
Circulation pump
Coolant cooler
Cooling fan
Sensor, coolant cooler