- ページ 6

水ポンプ Danfoss APP 2.5のPDF 分解と組み立ての説明をオンラインで閲覧またはダウンロードできます。Danfoss APP 2.5 12 ページ。
Danfoss APP 2.5 にも: 取扱説明書 (8 ページ)

Danfoss APP 2.5 分解と組み立ての説明
Disassembling and Assembling, APP 1.5-3.5
Service guide |
6 | 180R9091 | DKCFN.PI.013.EF5.02 | 521B0741
19. Position the new spring, new spring guide,
new retainer guide, new retainer plate and
new pistons.
21. Hold the pump together and carefully
turn it over to rest on the housing. To
prevent seizing-up, lubricate the threads
on the w screws and screw them into the
port flange and he housing. Use Molykote
D paste from Dow Corning or Klüber
UH1 84-201 from Klüber lubrication.
Tighten the 2 flange screws ato a torque
ccording to exploded view.
23. Replace the O-ring on the SAE flange.
20. Position the housing on the port flange
and over the guide pin.
22. Mount the new shaft seal following the
instructions on the next pages.
Wet torpedo and new shat seal with
soap. Do not use silicone grease.
Slide the shat seal over the torpedo with
carbon seal free face pointing upwards. Be
careful not to damage the carbon seal
facon on the shaft seal.
24. Lubricate the threads on the 4 screws
with grease and screw them into the
pump and tighten by hand. Use Molykote
D paste from Dow Corning or Küber UH1
84-201 from Küber Lubrication.
© Danfoss | DCS (im) | 2017.08