Encoder input 2, MK3D (slave):
Terminal designations ................................................................................................... A2, A2, B2, B2, Z2, Z2
Incremental:
Signal level ................................................................................................................................... 5 V differential
Signal type ............................................................................................................................. Linedriver, RS422
Input impedance ...................................................................................................................................... 140 Ω
Maximum frequency ........................................................................................... 220 kHz (at 50 % duty cycle)
Phase displacement between A and B ............................................................................................... 90° ±30°
Absolute:
Signal level ................................................................................................................................... 5 V differential
Signal type .................................................................................................................................................... SSI
Protocol ............................................................................................................................................ Gray code
Data length ............................................................................................................................................... 25 bit
Parity .......................................................................................................................................................... none
Clock frequency ....................................................................................................................... 105 or 262 kHz
Maximum positions per revolution ............................................................................................................. 8192
Maximum number of revolutions ............................................................................................................... 4096
Encoder cable
Cable type.............................................. ...............Twisted pair and screened. Note:
Cable length...........................................................Observe the prescriptions of the encoder supplier.
Absolute encoder is tested ok up to 150 meter cable at 105 kHz clock and 100 m at 262 kHz clock.
(Tested with TR electronic encoder type CE-65 M 8192*4096 and appropriate cable prescribed by TR electronic)
Maximum allowed time delay between clock and data signal measured at the controller terminals
Encoder output, MK3B:
Terminal designations ................................................................................................... A1, A1, B1, B1, Z1, Z1
Signal type ............................................................................................................................. Linedriver, RS485
Maximum frequency ............................................................................................................................. 150 kHz
Minimum frequency ................................................................................................................................ 150 Hz
Maximum number of slaves ........................................................................... 31 (more when using repeaters)
Maximum cable length ............................................................................................................................ 400 m
Dip switch 1.1 – 1.5
Switch
designation
OFF
1.1
Option card must be supplied from an
external power supply (24 V)
1.2
Terminating resistor not connected (Z channel)
1.3
Terminating resistor not connected (B channel)
1.4
Terminating resistor not connected (A channel)
1.5
Option card must be supplied from an
external power supply (Common)
Default setting of switch 1.1 - 1.5 is ON.
SW. 1.2, 1.3 and 1.4 applies only to MK3B (the master encoder interface).
NB!
When using the virtual master function termination must be switched off (sw 1.2-1.4) in all options
except on the first and the last station connected in the network.
6
VLT
®
5000 SyncPos option
the prescriptions of the encoder supplier.
ON
Option card is supplied from control card
(24 V)
Terminating resistor connected (Z channel)
Terminating resistor connected (B channel)
Terminating resistor connected (A channel)
Option card is supplied from control
card (Common)
MD.50.B2.02 – VLT is a registered Danfoss trade mark
Note: Please observe
Note:
Note:
Note:
9 µsec
105kHz clock =