- ページ 5

コントローラー DUOmetric LVBのPDF 技術情報をオンラインで閲覧またはダウンロードできます。DUOmetric LVB 12 ページ。

DUOmetric LVB 技術情報

LEDs

LEDs
LEDs
LEDs
The LVB indicates operational errors and faults via the eight adjacent LEDs RX, TX,
A... F. If the status is normal, LEDs C, D, E, F indicate the signal strength.
Please note that the error cannot be localized with 100 percent accuracy. The LEDs
only provide you with a good idea of where to start looking.

LED A

LED A
LED A
LED A
Signal
A (yellow)
illuminated

LED B

LED B
LED B
LED B
Signal
Even flashing
(approx. 2 Hz)
Continuously on
or off

Fault LEDs

Fault LEDs
Fault LEDs
Fault LEDs
Signal
RX (red)
illuminated
RX & TX
illuminated

Special LED combinations

Special LED combinations
Special LED combinations
Special LED combinations
Hardware fault, please inform
manufacturer
Length of connected rods
does not correspond with
stored values => perform self-
comparison (self-test)
Status
Warning
serial communication "crashed", defective
Fault
Receiver
Control unit
Technical Information
Possible causes
Blanked beams, watchdog.
Status
Normal operation.
Signal
TX (red)
illuminated
Hardware fault, please
inform manufacturer
LVB
Fault
Transmitter
Page 5 of 12