Setup
To enter the setup mode (Fig. 3) press and hold button 1
for more than a second.
From here use buttons 2 (UP) and 4 (DOWN) to cycle
through the menu screens and button 6 to accesss the
selected menu screen (Fig. 4).
Buttons 2 and 4 can then be used to alter the alarm
Fresh Air Correction & Calibration
CO
Fresh Air Correction
2
It is strongly suggested that the unit be corrected in a sunny, outdoor environment that is well ventilated. Do not correct
the unit in places crowded with people or close to areas with high CO
fireplaces.
To correct the unit for CO
unit will flash continually for about 5 minutes, then return to normal operation.
To abort correction at any time, simply turn the meter off.
CAUTION: The meter is corrected at ambient air of around 400ppm. Do not correct the meter in an environment with an
unknown CO
concentration. Doing this could lead to inaccurate measurements.
2
Specification
CO
2
Range of 0 - 9999
ppm
(maximum alarm threshold 9900
Resolution of 2
ppm
Accuracy ± 75
±5%
ppm
Temperature
Range of -10 - 60 ºC (14 - 140 ºF)
Resolution of 0.1 ºC (0.1 ºF)
Accuracy ± 0.6 ºC
Warm Up
30 seconds
Operating Ranges
From 0 ~ 50 ºC , 0 ~ 95% RH (avoid condensation)
Storage
From -20 ~ 60 ºC , 0 ~ 99% RH (avoid condensation)
Power
4 pcs AA batteries, DC Adaptor
Battery Life
> 10 hours (Alkaline)
w: www.duomo.co.uk
-
, place the meter in the calibration site and press and hold buttons 2 and 3 simultaneously. The
2
)
ppm
threshold on menu P 1.1 and the temperature scale on
menu P 3.1 (Fig. 4).
Use button 6 to save the current setting and return to
the main menu screen (Fig. 3).
Press button 3 at any time to exit the setup menu.
2
Troubleshooting
Can't power on
Press button 1 for more than 0.3 seconds and try
again. Check whether batteries are in good contact
and correct polarity is observed.
Fixed readings
Check whether data hold function was activated.
Slow response
Check whether the air flow channels on the rear are
blocked.
Error messages
E01: CO
2
E02: The value is under range
E03: The value is over range
E04: The original data error results in this error
E07: Voltage to measure CO
use an adaptor
E17: Retry CO
E31: Temperature sensor damaged
-
t: 01905 797989
-
concentration such as ventilating outlets or
sensor damaged
. Replace batteries or
2
calibration
2
f: 01905 774296
|
© Duomo (UK) Ltd. 2007