The electric supply connection shall be made by a qualified electrician and comply with IEC 60364-1.
It is recommended that the electric supply to this machine should include either a residual current device that
will interrupt the supply if the leakage current to earth exceeds 30ma for 30ms or a device, which will prove
the earth circuit.
SAFETY VALVE This machine is equipped with two safety valves, able to ensure the safety of the
machine itself in case other primary control devices are inefficient (due to a failure). Due to the extreme
importance of these components and as not to compromise the safety of the machine, it is recommended to
provide to check them and to substitute them through an authorized service center every 2 years starting from
the purchasing date.
PRESSURE SWITCH This machine is equipped with a pressure switch able to check and to maintain the
pressure under certain preset limits (ref. "rated pressure" on the technical label underneath the machine). In
case there would be a steam leakage on the lower side of the machine, it means that the functioning of this
device has been compromised and the safety valve has been involved as to limit the boiler's internal
pressure. It is recommended not to use the machine, immediately unplug the machine
from the power feeding and call the service center.
CALCIUM DRAIN FROM THE BOILER If you are not acquainted with the hardness level of the used
water, it is recommended to proceed with the boiler cleaning (according to the procedure indicated in the
proper section) after 24 hours of usage. On the contrary, if you know the hardness level and it is between 0
and 4 French degrees , the boiler cleaning can be carried out after 100 hours of usage.