- ページ 5
舶用機器 Daniamant L160のPDF インストールとメンテナンスの説明書をオンラインで閲覧またはダウンロードできます。Daniamant L160 6 ページ。 Mounting adapter plate
Maintenance
Routine service
The L161 and L163 is maintenance free, but the following checks should be made periodically (e.g.
annually):
1. Inspect visually to ensure the casing is undamaged and that no component parts are missing or
damaged. If damaged, the unit is to be replaced.
2. Carefully extract the unit from its housing, taking care not to activate the light.
3. Manually activate the switch slider on the side of the lower portion of the case.
4. Ensure that the light functions. If the light fails to function, the unit is to be replaced.
5. Return the switch slider to the off position to extinguish the lamp, making sure that the release
toggle is still attached to the switch.
6. Finally replace the unit into the housing.
Please note there are no user serviceable parts inside this light. If the light fails to illuminate during test,
it needs to be replaced. Tampering with the unit will void any warranty.
Spares
The following spares are available to support the L161 and L163
— L161/L163 Bracket. Part Number 62116
— Adaptor Plate. Part Number 62070A
Spares are available from our distributors around the world.
Release toggle attached, and
switch moved to off position.
Replace light in bracket. Ensure lanyard is located in recess.