- ページ 11

アンプ Conrad-Johnson ART 150のPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Conrad-Johnson ART 150 11 ページ。

Conrad-Johnson ART 150 オーナーズマニュアル

Specifications

Power: 150
30Hz to 15KHz at no more than 1.5% total harmonic distortion
(can be re-connected internally for 16 ohm loads).
Sensitivity: 1.0 V rms to rated power
Small Signal Distortion: less than .25% at mid-band
Frequency Response: 20Hz to 20 kHz +0/-.25 dB
Hum and Noise: 108 dB below rated power output
Phase: phase correct
Input Impedance: 100 kOhms
Tube Complement: 3 x 6922, 4 x KT150
Important Note: output tubes must be replaced with matched pairs
selected for use in this amplifier.
Mechanical
Dimensions: 16.3125"D x 19"W x 8.75"H
Net Weight: 80 lb net
Fuses
The ART 150 Amplifier power transformer is protected by a fuse
on the ac power line (F5, located in a compartment in the ac line-
cord receptacle mounted on the back of the amplifier), and by four
separate internal fuses on the secondary circuits of the transformer
(F1 – F4) located on the bottom of the pc board. A failure of any of
these fuses is a symptom of a more serious problem, and a
competent service technician should be consulted. In no event
should fuses be replaced with a value or type different than that
originally supplied. The correct fuse values and types are:
Watts rms both channels driven into 4 ohms from
F5:
5x20mm 12 amp T-type if configured for 100 or 120V:
5x20mm 6.3 amp T-type if configured for 220 or 240V.
F4:
5x20mm 3.15 amp T-type
F1, F2, and F3: 5x20mm 200ma T-type
Conrad-Johnson ART 150 Amplifier Owner's Manual
10