- ページ 5
ゲートオープナー Casit EQ2009のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Casit EQ2009 14 ページ。 Control box gate's opening
4.2) DIP-SWITCH S3 FUNCTIONS
ON
Test photocells on FOTO 1 on.
DIP 1
OFF Test photocells on FOTO 1 off.
ON
Test photocells on FOTO 2 on.
DIP 2
OFF Test photocells on FOTO 2 off.
Working type B
ON
DIP 3
(it trains the card for signal clinking LAMP and it changes the work formality of the input Safety edge 1 and 2.).
OFF Working type A (standard).
ON
Survey obstacle (reverser ampherometric) on both motors excluded.
DIP 4
OFF Survey obstacle (reverser ampherometric) on both motors active.
ON
Setting of survey obstacle power in slowing down on both motors for a high range of force
DIP 5
OFF Setting of survey obstacle power in slowing down on both motors for a low range of force
Maximum power to the motors M1 and M2 in closing in the last 2", ON.
ON
Maximum power in closing in the last 2" ON, only for motor M1( M2 does not work is that the close limit is on that
DIP 6
OFF
is off). Default Casit.
ON
After pedestrian opening of M1, close in both M1 M2(if close limit switch of M2 is on, M2 does not work).
DIP 7
After pedestrian opening of M1, closes only M1(M2 does not work
OFF
off)
. Default Casit.
ON
The output light of courtesy is immediately disarmed at the end of closing.
DIP 8
OFF The output light of courtesy is disarmed three minutes later than the end of closing.
During the opening and the closing, it stops the movement and reopens
ON
totally when obstacle removed.
DIP 9
In closing, the gate stop, and then manoeuvre in the opposite way.
OFF
In opening it doesn't works.
In opening and in closing, the gate stop, and then manoeuvre in the
ON
opposite way for 2 sec. but 1 minute later it closes.
DIP 10
In opening, the gate stop, and then manoeuvre in the opposite way for 2
OFF
sec. but 1 minute later it closes. In closing it doesn't works..
DIP-SWITCH FUNCTIONS S4 SELECTION MOTOR WITH/WITHOUT ENCODER – WITH WITHOUT LIMITSWITCHES
4.3)
FUNCTIONS DIP 1 and 2
DIP1 - Selection motor with/without encoder.
DIP2-Selection function/connect limit switch.
OFF
STANDARD MOTOR WITHOUT ENCODER
DIP 1
ON
MOTORS WITH ENCODER
Test triac off.
ON
switches on the motor phases
DIP 2
Test triac on.
OFF
switches
Casit.
CONNECTIONS J1 RX = graft for the receiver.
5) DEFAULT TIMES
The control panel foresees some times of work pre setted:
time of work on 2 motors = 50 seconds; time of pedestrian opening = 10 seconds
time - break = 8 seconds; time of pedestrian break = 8 seconds
leaf delay in opening = 3 seconds; leaf delay in closing = 5 seconds
To eliminate the leafs delay (or if you used one motor only) select the time of unified work for both the motors on the motor M1 S1-
dip 5 ON , it's good for default times only.
6) TIME OF COMPENSATION
To balance the differences of speed between the opening and the closing of the gate during the run, or to balance the different
speeds during an inversion of the run, especially if the last part of the stroke has the speed of deceleration, the control panel has
balance times at the end of time of work in 3 sec. if the slowing is not used and 6 sec. if slowing is working.
7) DEVICES OF PLANNING
The pushes button PS1s (START), PS2 (Pedestrian), PS3 and the leds L14, L15, L16 are used for the formulation of the parameters
in the planning menu (see chapter 8).
Page 5 of 14
To connect the limit
.
To connect the limit
a 20,21,22,23,24 di M9. Default
SEE CHAPTER 11 ABOUT OPERATION WITH ENCODER
whether the close limit switch is on that is
DIP3
MOTORS WITH OR WITHOUT LIMITSWITCHES
The participation of the encoder/reverser inverts the motion
ON
of the gate till the activation of the limitswitch closes.
USE IT WITH MOTORS WITHOUT LIMITSWITCHES
During the last 6 sec. of the stroke, the working of
OFF
encoder/reverse it stops the gate without reverse.
USE IT WITH MOTORS WITHOUT LIMITSWITCHES
EQ2009 R 1.6 1.8
PHOTO 2
Motors
with encoder
PHOTO 2
FUNCTIONS DIP3
Rev. 02 del 2/05/2011
only