10. Open Window Detection
Ensuring you don't waste energy on heating the outside
world, the heater is equipped with optional open /
closed window detection. The heater recognises sudden
drops in temperature when a window or a door is
opened and turns the heating off to save energy. When
the window is closed, the heater will automatically
detect a temperature rise, and switch itself back on.
Once enabled in the setup menu, the open window
detection is fully automatic and does not require any
human intervention to be activated.
Setting-up Open Window Detection
The system has been factory set to default time and
temperature values. If necessary, all values can be
adjusted. When the heating is on, open window
detection sensor will automatically switch the heater off
when it detects a fall in temperature of 2 ° C in less than
10 minutes (this temperature can be changed in menu 7
and time in menu 6). If a temperature rise of 2 ° C in less
than 30 seconds is detected, the heater will switch itself
back on (this temperature can be changed in menu 9
and time in menu 8). These changes can also be made
in the app. When viewing the heater settings, select the
'open window detection' menu.
11. Optional PLK1 Locking Device
The PLK1 locking device can be used to mechanically
lock the controls to prevent tampering with settings. As it
is not supplied with the heater, kindly contact our Sales
team if required.
- Locking tab
- Locking screw
Locking tab
12. Keys locking
Press and hold TIME and TEMP together for 5 seconds. The
display will show
symbol. Repeat the step to unlock.
13. Heat symbol on the display
Every time there is a demand for heat, the display will
show the heat icon.
15. Setup menu
1.
2.
3.
4.
01 - temperature calibration
The temperature reading has been factory calibrated
but if for any reason it needs adjusting (better accuracy
required, to suit different position in the room etc.), the
reading can be recalibrated in 0.5 degrees steps.
02 - change between degrees Celsius or Fahrenheit
03 - set minimum temperature
When this is set, the heater will operate in any mode
should the room temperature fall below the set
temperature.
04 - set maximum temperature
When this is set, the maximum temperature in any mode
cannot exceed the limit.
05 - open window detection 0 = off, 1 = on
06 - 600 - open window detection time 600 seconds
07 - 2 - temperature drop of 2°C in the detection time
08 - 30 - closed window detection time of 30 seconds
09 - 2 - temperature rise of 2°C in the detection time
Please note: Settings a to e are only applicable to MWIFI
models.
a - Enable occupancy sensor
b - Occupancy sensor time out
c - Self learning enable
d - Occupied Temperature
e - Unoccupied temperature
Locking screw
- full heat output
Press and hold TEMP and MODE together for 5
seconds.
The display will enter the setup menu.
Use TEMP and MODE to change a value.
Use TIME to scroll between the settings.
°C
(4
= frost protection)
66001328 Iss 01