- ページ 8

薪ストーブ Cast S226SのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Cast S226S 16 ページ。

It is recommended that the stove be installed at least 400 mm from combustible
materials. However, any household furnishings should be at least 1000mm away as
they could be adversely affected by heat.
If the stove is to be installed in a non combustible recess it is recommended that
100mm clearance is left at the back and sides for maintenance and to allow air to
circulate around the stove
Due to the heat of a hot stove, a suitable fire guard should be used to provide
additional protection. Never allow young children to be left unsupervised in a room
containing a hot stove.
Floor
National and local building regulations must be complied with when considering the
floor or hearth where the stove is to be installed. The floor must be capable of
bearing the weight of the stove and the maximum hearth temperature measured on
testing was 49 deg C on full fire.
The Chimney
The stove is supplied with a flue pipe connector for top or rear mounting with the
fixing screws supplied. The stove should never be connected to a shared
chimney/flue system.
Flue pipes with a smaller cross-sectional area than that of the stove outlet should
never be used. Flue pipes must not project into the chimney connector, such as to
cause a restriction to the gas flow.
Consideration must be given to installing extra access in the flue system to ensure all
sections can be cleaned and maintained.
Fume Emissions
To avoid chimney problems, your fire should not be burnt slowly for longer than 12
hours without a period of fast burning.
Properly installed and operated, this stove will not emit fumes. Occasional fumes
from de-ashing and refueling may occur. Persistent fume emission must not be
tolerated. If fume emission persists, the following immediate action should be taken:
8