- ページ 9

ヒートポンプ Duratech DURAPRO-12のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Duratech DURAPRO-12 14 ページ。

Duratech DURAPRO-12 マニュアル

4.3 Error codes

In the main screen, tap the Error codes button.
A new menu will pop up:
If there are no error codes present, the main display will show a grey triangle logo:
When an error occurs, the error icon will flash orange/grey:
the system will record the time, code and name of the error.
When an error occurs, and you don't check the Error code history menu, the main interface will
display a static "
" icon after a while.
If you do check Error code history menu, the main interface will display a static "
The Error code history meny shows all the error codes in reverse order, with the most recent code
on top. If you tap the "Clean" key, you can erase all the codes.
16

4.4 Error code list

Protect/fault
Standby
Normal boot
Inlet temp. Sensor failure
Outlet temp. Sensor failure
Coil temp. Sensor failure
Ambient temp. sensor failure
Suction temp. sensor failure
Exhaust temp. sensor failure
High pressure protection
Low pressure protection
Flow failures
System anti freezing
" icon.
protection
The primary anti-freezing
protection
The secondary
anti-freezing Protection
Water-inlet and outlet temp
Low temperature protection
Compressor too much
electricity protection
Exhaust Temp. Of system
is too high
Communication failure
Fault
Reason
Elimination methods
display
non
non
The temp. Sensor is broken
Check or change the
P01
or short circuit
temp. Sensor
The temp. Sensor is broken
Check or change the
P02
or short circuit
temp. Sensor
The temp. Sensor is broken
Check or change the
P04
or short circuit
temp. Sensor
The temp. Sensor is broken
Check or change the
P05
or short circuit
temp. Sensor
The temp. Sensor is broken
Check or change the
P07
or short circuit
temp. Sensor
The temp. Sensor is broken
Check or change the
P081
or short circuit
temp. Sensor
The high-presesure switch is
Check the pressure
E01
broken
switch and cold circuit
Check the pressure
E02
Low pressure1 protection
switch and cold circuit
No water/little water in
Check the pipe water
E03
water system
flow and water pump
Check the pipe water flow and whether
E07
Water flow is not enough
the water system is jammed or not
E19
The ambient temp. Is low
E29
The ambient temp. Is low
Water flow is not enough
Check the pipe water flow and whether
E06
and low differential pressure
the water system is jammed or not
non
The environment temp. is low
Check whether the system of
E051
The compressor is overload
the compressor is running normally
Check whether the system of
P082
The compressor is overload
the compressor is running normally
Communication failure between
Check the wire connection between
E08
wire controller and main board
remote wire controller and main board
17