- ページ 8
マルチメーター Duratool D03046のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Duratool D03046 10 ページ。
Duratool D03046 にも: 取扱説明書 (8 ページ)
2. Set RANGE switch to desired DCA position.
3. Open the circuit to be measured, and connect
test leads IN SERIES with the load in
with current is to measure.
4. Read current value on Digital Display.
5. Additionally, "5A" function is designed for
intermittent use only. Maximum contact time of
the test leads with the circuit is 10 seconds,
with a minimum intermission time of 15
minutes between tests.
RESISTANCE MEASUREMENT
1. Connect red lead to "VΩmA". Connect black
lead to "COM".
2. Set RANGE switch to desired Ω position.
3. If the resistance being measured is connec-
ted to a circuit, turn off power and discharge all
capacitors before measurement.
4. Connect test leads to circuit being measured.
5. Read resistance value on Digital Display.
DIODE MEASUREMENT
1. Connect red lead to "VΩmA". Connect black
lead to "COM".
2. Set RANGE switch to "
3. Connect the red test lead to the anode of the
diode to be measured and black test lead to
cathode.
4. The forward voltage drop in mV will be
displayed. If the diode is reversed, figure "1"
will be shown.
" position.
- 8 -