マルチメーター Duratool D03125のPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。Duratool D03125 8 ページ。 3 1/2 digital multimeter

Duratool D03125 クイック・スタート・マニュアル
Range
Overload protection: 250V DC or RMS. AC.
Range
Resolution
°C

OPERATION

Plug the instrument in and check the 9V battery. If it is low the "
symbol will display, meaning the battery needs replacing.
The
besides the probe jack indicates that the input voltage or current
!
should not exceed the specified limits, in orderto protect the internal
circuit.
Before measurement, turn the function/range switch to the desired range.
Direct Voltage Measurement
Insert the red probe into the "VΩmA" jack and the black one into the COM
jack.
Turn the function/range switch to the range of V
to the power supply or load to be measured. The polarity touched by the
red probe will be on the display.
Notice
If you do not know the measured voltage range in advance, set the
function/range switch to the maxium range and then gradually turn to
smaller ranges until you reach a satisfactory resolution.
If the display shows " 1 ", this indicates an overrange measurement,
therefore the switch should be set to a higher range.
Do not input a voltage of more than 600V. It is capable of indicating a
higher voltage, but with the risk of damaging the inside circuit.
When taking the measurement of high voltage, pay special attention to
avoid an electric shock.
Diode and Circuit On-Off Measurement
Description
When the on-resistance is smaller than (70±30)
built-in buzzer will sound.
Displays the approximate diode postive voltage.
Temperature Measurement
Measurement
-20°C to 0°C
1°C
-0°C to 400°C
400°C to 1000°C
±10% Range, ±2 digits
±1.0% Range, ±3 digits
±2.0% Range
6
Ω, the
Accuracy
"
+ -