- ページ 2

計測機器 Duratool D03309のPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。Duratool D03309 3 ページ。 Pocket moisture meter

Duratool D03309 クイック・スタート・マニュアル
IMPORTANT SAFETY INFORMATION
Please read these instructions carefully before use and retain for future reference.
When using electrical appliances basic safety precautions should always be
followed.
There are no user-serviceable parts in this product. Refer servicing to qualified
personnel.
This appliance is not intended for use by persons (including children) who are not
mentally able, physically capable, experienced or do not understand the product.
They should be given supervision and instruction in the use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Never place the product or part of it in water.
Always observe the safety instructions and applicable regulations.
Replace the batteries as soon as the low battery indicator appears on the display.
Fit a full set of batteries at one time.
Remove dead batteries from the appliance or if it is not going to be used for a long
time.
Only use the batteries recommended for this product.
Ensure that the batteries are inserted correctly, observing the correct polarity.
Never mix old and new batteries together, or different types of batteries.
Never dispose of batteries in a fire, or attempt to recharge ordinary batteries.
WHAT'S INCLUDED
Moisture Meter
Batteries 4 off
Instruction manual.
OPERATION
Remove the probe cover from the top and store it by placing it on the bottom of the
casing and the Instrument switches on automatically.
Press the measuring electrodes as far as possible into the material.
Read the measurement shown on the LCD dual display (moisture/temperature).
Always measure the moisture in wood perpendicular to the fibre structure.
Repeated measuring yields representative data.
Once all measurement is completed, press the on/off key for about 2 seconds and
the meter will power off.
FUNCTIONS
ON/OFF Button
Long press (2 seconds) to turn the meter on or off.
Auto Power Off
After approximately 2 minutes where no operation of the meter is made, the meter
will enter auto power off state.
Pressing any button will power the meter back on again and continue the previous
function setting.
To prevent auto shut down press and hold the MODE button while powering on the
meter.
Backlight
Short press the on/off button to operate the backlight function.
Mode Button
Long press (2seconds) to switch between Celsius/Fahrenheit modes.
Short press for wood/material humidity measurement function.
Memory Function
The instrument has internal memory and retains the last used settings and modes
after being switched off and on again.
CLEANING
Wipe the outer casing with a damp cloth and a mild detergent.
Do not use any chemicals, abrasives or solvents that may damage the instrument.
Prevent dirt from accumulating between the probes.
SPECIFICATION
Measuring Principle
Electrode Length
Electrodes
Measurement Range
Resolution
Accuracy
Auto Power Off
Batteries
Working Environment
Electrical resistance
8mm
Integrated
Wood: 6 - 44%
Masonry: 0.2 - 2.0%
Wood: 1%
Masonry: 0.1%
Temperature: 1
o
C
Wood: ± 2%
Masonry: ± 0.2%
Temperature: ± 1
o
C
After approx 2 minutes
4 off LR44 Alkaline
0 - 50
o
C / 0 - 85% Relative Humidity