- ページ 5

掃除機 DURAVAC EU VH0423 SUBのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。DURAVAC EU VH0423 SUB 12 ページ。 Wet & dry vacuum cleaner

EU VH0423 SUB
Always disconnect power cord from power source after operating and before
servicing. After every use and before sending the appliance to technical assistance,
the vacuum cleaner must be disassembled, cleaned and overhauled to avoid
hazard for the maintenance staff.
• Do routine maintenance. Inspect gaskets seals, plastic parts, filters, switches and
replace those which have begun to leak or are damaged.
• Using a machine with a damaged power cord could result in an electrocution Check
the cord looking for cut, cracks or aging signs and replace it, if it's necessary.
• Only an authorized service centre can replace power cord of the appliance.
• If extension cord are used, ensure that the cable rating is suitable for use with the
equipment. Keep dry at all times. Avoid contact with conductive surfaces.
• Don t let children clean the appliance if they are not under supervision of an adult.
• Only an authorized service centre can do reparation or maintenance of the
appliance. Use only original spare parts.
• To keep the appliance fully functional it is necessary to clean polyester filter shaking
it after every use and replace filtering bag if it's full.
• Clean every part of the appliance after each use: empty the tank, shake the filters,
replace filtering bag if it's full and clean the machine with a damp cloth before storing the
vacuum cleaner.
WARNING: in case of foam or liquid leak switch off the appliance immediately,
WARNING: in case overturning, lift the appliance in the upright position before
switching the motors off.
• Don't pick up water from sink or tub. Do not use cleaner as a pump to clean out
clogged drains, sinks, or other plumbing fixtures. The vacuum cleaner is intended for
vacuuming air and water mixtures.
• Do not use or pick up aggressive soaps, they could damage the appliance.
WARNING: The floater switch has the function to stop the vacuuming when the tank
is full of liquids or in case of overturning; carry out cleaning routine checking that
there are no damages and change it if it's necessary.
WARNING: Do not use outdoors or in a cold environment.
NOISE
Values measured according to EN 60704-1 (2010) / EN 60704-2-1 (2001) ISO 3744 standards.
The sound pressure level weighted A of the appliance is LpA=77.5 dB; KpA=2.5 dB.
VIBRATIONS
Hand-arm vibrations on the suction hose are less than 2,5 m/s
5349-1
Under adverse network conditions, the appliance may cause temporary drops in voltage.
NOTHING IS TOUGHER
2
as recommended by ISO
5.