HEARTH EXTENSION REQUIREMENTS
HEARTH EXTENSION ON WOODEN FLOORS
When the fireplace is installed over a wood flooring, a non-combustible hearth extension must be constructed.
This extension must be the same thickness as the heat shield or block pedestal that was fabricated to support
the fireplace (see page 8).
Model
PFM36
PFM42
PFM48
PFM60
FIG 14. hearth extension requirements
HEARTH EXTENSION ON CONCRETE FLOORS
The hearth extension on concrete floors that have been carpeted must conform to the same size as indicated for
the wood floor extensions. If the fireplace is set flush with the floor on split firebricks, a tile or stone hearth ex-
tension the same size must be maintained when the floor is carpeted. If the floor is covered with total non-
combustible material, this does not apply.
FINISHING FIREPLACE INTERIOR
Supplied with the fireplace is a can of liquid sealer, and a small paint roller. These are used to coat the brick inte-
rior of the fireplace after it has been installed. This optional step is purely for aesthetics, but provides a darker,
slightly wet look to the bricks.