- ページ 8

ネットワーク・ルーター Contemporary Research ICC1-IRのPDF 製品マニュアルをオンラインで閲覧またはダウンロードできます。Contemporary Research ICC1-IR 17 ページ。 Ir tv controller, 1-way rf coax control
Contemporary Research ICC1-IR にも: 仕様 (2 ページ)

Contemporary Research ICC1-IR 製品マニュアル
Installation

Setting Device Number and Parameters (Device Mode)

In the next step, you'll need to set up the device number and operation parameters for the ICC1-IR. Notice that
the functions of the S1 and S2 switches change when you set the unit in Device mode.
1. Make sure S2 Switch 6 is OFF (unit in Device mode).
2. Set the Device number by turning on the switches that add up to the desired device number. For
example, for Device #513 (1
3. IR Carrier: Set S2 Switch 5 to OFF to send carrier with IR commands (default), ON to turn off carrier.
4. Power Sense Level: Set S2 Switch 7 to ON for high sensitivity for power (default), set to OFF if you
need to lower sensitivity (usually 2 adjacent TVs – side-by-side or through a wall).
5. IR Out Level: Set S2 Switch 7 to ON for high signal level (default), set to OFF if you need to lower IR
signal level to TV.
S1
Off Value
1
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S2
1
0
2
0
3
0
4
0
5
IR Carrier On
6
Device Mode
7
Power sense low
8
IR Out low
*Values in gray cells are the default settings.

Zone Switch Settings

To define the controller's Zone, use the following pattern of switches ON for the S2 DIP.
Zone
1
2
3
4
1024
5
1280
6
1536
7
1792
8
2048
9
2304
10
2560
11
2816
12
3072
13
3328
14
3584
15
3840
Contemporary Research
st
device in Zone 2), S1 Switch 1 (1) and S2 Switch 2 (512) ON.
On Value
1
2
4
8
16
32
64
128
256
512
1024
2048
No Carrier
IR Program Mode
Power sense high
IR Out high
Value
1
2
256
512
256
X
512
X
768
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Device Number Setting
3
4
1024
2048
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
8
ICC1-IR IR TV Controller