- ページ 9

アクセサリー 4B HTAS1V34のPDF 操作マニュアルをオンラインで閲覧またはダウンロードできます。4B HTAS1V34 20 ページ。 Wda sensor belt alignment / motion & broken / slack chain monitor

4B HTAS1V34 操作マニュアル

BUCKET ELEVATOR PLACEMENT DIAGRAMS

HEAD
SECTION
OPTION 1 -
Steel Elevator Buckets
Mount WDA sensor on
side of elevator leg to
target the sides of the
rotating buckets
(Figure 2).
BOOT
SECTION
For bucket elevator installations, WDA sensors are designed to work in pairs. One pair mounted on
the head of the elevator leg and another pair on the boot section.
X
X
NOTE
PAGE 9
OPTION 2 -
Plastic Elevator Buckets
Mount WDA sensor on
back side of elevator leg
to target the elevator bolts
used to secure the plastic
buckets (Figure 6).
X
- Mount WDA sensor
within a few feet of
the pulley or as close
to this position as
possible.
Figure 1 -
Typical WDA Sensor
Positions On Up Leg
Of Bucket Elevator