- ページ 7

産業機器 4B RG1V56AのPDF 操作マニュアルをオンラインで閲覧またはダウンロードできます。4B RG1V56A 16 ページ。 Rotary level indicator

Before installation, inspect the outer structure of the level gauge. Check the movement of the propeller
shaft and the operation of the clutch assembly. If this check reveals anything irregular, the level gauge
must be reported back to 4B. 4B level gauges can be installed in any position. With the shaft in a horizontal
or vertical position, the level gauge must be mounted with cable glands on the right hand side (Figure 1).
The level gauge is mounted on silos or vessels on the side or top. It is important to choose the position
so that the device is outside of the product flow, likewise taking care that the material can move freely all
around the gauge.
Protective deflectors (Figure 2) are advisable when there is considerable weight load on the shaft or when
material flow is unevem and lumps of product may fall down on the probe. The level gauge can be mounted
on the silos via a threaded insert (2" 1/2 BSPP), which is welded onto a silo.

INSTALLATION

0
1
2
110
M
3
240
4
10A.250VAC
5
6
7
Figure 1 - Mounting position.
Figure 2 - Shaft protection.
PAGE 7