- ページ 8
掃除機 4CR 9500のPDF マニュアルをオンラインで閲覧またはダウンロードできます。4CR 9500 8 ページ。 Industrial vacuum cleaner
TROUBLESHOOTING AND SOLUTION
EFFECTS
The motor will not start
The vacuum does not start
automatically
Vacuum flow is insufficient
Dust from the exhaust
Tools do not start
Insufficient Power for pneumatic
tool
DISPOSAL (WEEE DIRECTIVE)
At the end of its useful life, the product, pursuant to European Directive 2002/96/CE (WEEE) + 2003/108/CE and its
implementation in national law, must not be released into the environment or thrown away as domestic waste, but must
be disposed of at authorized recycling centers (contact the relevant local authorities for a list of places where the product may
be disposed of according to the law). Disposing of the product correctly contributes to protecting human health and
safeguarding the environment. Any illegitimate disposal of the product will be punishable by law.
INDUSTRIAL VACUUM CLEANER EN
CAUSES
No power
Power cord, switch or motor defective
Electronic module
Bag full
One of the hoses or accesso ries is clogged
Clogged filters
Filter cartridge torn ripped
3-way switch malfunction
Insufficient compressed air feeding
SOLUTIONS
Make sure the unit is plugged in
Contact an authorised service centre
Contact an authorised service centre
Check the filter bag
Check the flexible hose and the
accessories
Check the filters cartridges
Contact an authorised service centre
Contact an authorised service centre
Check air passage
8