舶用機器 Apollo REACH WIRELESS RW1500-110APOのPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。Apollo REACH WIRELESS RW1500-110APO 4 ページ。 Open-area wall sounder

Apollo REACH WIRELESS RW1500-110APO クイック・スタート・マニュアル
Status LED
The REACH Wireless Open-Area Wall Sounder VAD Base
includes a 360° LED indicator which to indicate status
conditions. See table 1.
Table 1: REACH Wireless Device Status & LED
Indication
Device Status
Tamper Not
Power Up
Power Up (dip-switch ON)
Blinks alternatively green/red four
Entering Wake-Up
Link Success
Enters wake-up mode and signals
Link Failure
'Entering wake-up mode' following
Normal Condition
Activation
Battery Faults
Tamper Fault
Replaced
Tone & Volume Selection DIP Switch Settings
Device Addressing
Device addressing is handled by the REACH Wireless Loop-
Interface device (RW1700-030APO).
Devices are soft-addressed automatically when pairing with
the Loop Interface and can be changed manually. Hard-
addressing using Apollo XPERT cards are not supported.
Table 2: REACH Wireless DIP Switch Functionality
DIP Switch
DIP Switch Group Function
Number
1
2
3
Tone Selection
4
5
6
Volume Selection
7
8
High/Low Power LED Output
LED Indication
Tamper
Activated
Activated
Blinks green four times
Blinks red four times
times
Blinks green four times, then
repeats
this failure
LED off
LED off
LED off
Red on
Amber blinking
LED off
every 5s
LED off
Blinks amber two times
Notes
Check Tone Table
(Table 4)
Check Volume
Table (Table 3)
N/A
Table 3: REACH Wireless Volume Table
Volume
High*
Medium High
Medium Low
Low
*EN54-3 certified, for Tone Table (Table 4), see appendix
Communication
REACH Wireless Devices use 'radio-frequency' wireless com-
munication to connect to the Loop-Interface.
The Loop-Interface (RW1700-030APO) translates the wire-
less communication into wired Apollo protocol communica-
tion, with each device addressable individually by the fire
panel. See datasheets for the Loop-Interface for more infor-
mation.
Maintenance and Service
Maintenance must be performed in accordance with all
applicable standards. Clean the detector externally using a
soft damp cloth. For full cleaning and recalibration detectors
should be returned to Apollo Fire Detectors.
Batteries
REACH Wireless devices are supplied with two CR123 bat-
teries, battery A and B. The device switches periodically
between the two batteries on a controlled sequence. For cor-
rect operation of the device, both batteries are required with
adequate capacity reserves.
When battery A reaches a low power threshold, it will trig-
ger a fault. This fault requires both batteries to be replaced
in every instance as both batteries should be discharging
equally.
When one (or both) batteries lack power, the Loop-Interface
receives a low battery message and will signal this event on
its in-built display, as well as relay the low battery message
to the fire control panel. The battery fault will also be sig-
nalled by the device itself through its LED indicators if pro-
grammed (see table 1).
Tamper detection
REACH Wireless devices contain an anti-tamper mechanism.
In the event of removal from its base, it sends a tamper de-
tection message to the Loop-Interface.
Tampering detection is not signalled visually by the device
LED.
EMC Directive 2014/30/EU
REACH Wireless Open-Area Wall Sounder complies with the
essential requirements of the EMC Directive 2014/30/EU,
provided that it is used as described in this datasheet.
A copy of the Declaration of Conformity is available from
Apollo on request.
PP5105/2022/Issue 1
Page 2 of 4
DIP Configuration
11
01
10
00