- ページ 2
セキュリティシステム Apollo 33 404のPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。Apollo 33 404 2 ページ。 Sounder beacon base with isolator
DIL switch
DIL switch
setting
setting
addr
1234567
addr
1234567
addr
1
1000000
11
1101000
2
0100000
12
0011000
3
1100000
13
1011000
4
0010000
14
0111000
5
1010000
15
1111000
6
0110000
16
0000100
7
1110000
17
1000100
8
0001000
18
0100100
9
1001000
19
1100100
10
0101000
20
0010100
51
1100110
61
1011110
52
0010110
62
0111110
53
1010110
63
1111110
54
0110110
64
0000001
55
1110110
65
1000001
56
0001110
66
0100001
57
1001110
67
1100001
58
0101110
68
0010001
59
1101110
69
1010001
60
0011110
70
0110001
101
1010011
106
0101011
111
102
0110011
107
1101011
112
103
1110011
108
0011011
113
104
0001011
109
1011011
114
105
1001011
110
0111011
115
Group Address Setting
In group mode the Sounder Beacon Base responds to an additional address referred to as the
group address, which is used to activate groups of Integrated Base sounders and/or 100dB
open area sounders simultaneously. Individual units continue to respond to their own addresses
and report their status in the normal way. A group address is set on a four-segment DIL switch
which is factory set to 0000. A group address may be any spare address within–and only
within–the range 112 to 126 inclusive. The required group address is set in accordance with the
following table. For an illustrated example, please see Fig 1.
DIL switch
DIL switch
setting
setting
addr
1234
addr
1234
addr
112
1111
117
0101
122
113
0111
118
1001
123
114
1011
119
0001
124
115
0011
120
1110
125
116
1101
121
0110
126
Note: group mode is disabled if the group address DIL switch is
set to 0000, irrespective of the protocol message.
Testing
The product is tested via the control panel. Output bit 0 is set to
1 on two polling cycles to switch on the product which should
be tested for at least 5 seconds.
Commissioning
It is important that the product be fully tested after installation. An XP95 Test Set, part no
55000-870, may be used to carry out functional testing of individual units. The test set can also
perform data integrity tests of an entire system.
DIL switch
DIL switch
setting
setting
1234567
addr
1234567
addr
21
1010100
31
1111100
41
22
0110100
32
0000010
42
23
1110100
33
1000010
43
24
0001100
34
0100010
44
25
1001100
35
1100010
45
26
0101100
36
0010010
46
27
1101100
37
1010010
47
28
0011100
38
0110010
48
29
1011100
39
1110010
49
30
0111100
40
0001010
50
71
1110001
81
1000101
91
72
0001001
82
0100101
92
73
1001001
83
1100101
93
74
0101001
84
0010101
94
75
1101001
85
1010101
95
76
0011001
86
0110101
96
77
1011001
87
1110101
97
78
0111001
88
0001101
98
79
1111001
89
1001101
99
80
0000101
90
0101101
100
1111011
116
0010111
121
0000111
117
1010111
122
1000111
118
0110111
123
0100111
119
1110111
124
1100111
120
0001111
125
126
Individual Address
DIL switch
O
setting
1
1
2
2
3
3
4
4
N
1234
= 0 1 0 1 0 1 0
1010
0010
= Address 42
1100
0100
Group Address
1000
O
N
1
1
2
2
3
3
0 1 1 1 = Address 113
©Apollo Fire Detectors Ltd 2003-6 RHD/JLC/RHD
Fig. 1 Address example
2
XPERT Card Addressing
DIL switch
Select the desired address and remove the pips indicated in black. Remove pips with a small
setting
screwdriver.
1234567
1
1001010
1
0101010
1101010
0011010
1011010
16
0111010
16
1111010
0000110
1000110
0100110
31
1101101
31
0011101
1011101
0111101
1111101
46
0000011
46
1000011
0100011
1100011
0010011
61
61
1001111
0101111
1101111
0011111
76
1011111
76
0111111
91
91
106
106
5
5
6
6
7
7
8
8
121
121
0 = 55–65dB(A)
1= 65–84dB(A)
Technical Data
4
4
2
3
4
5
6
7
8
2
3
4
5
6
7
8
17
18
19
20
21
22
23
17
18
19
20
21
22
23
32
33
34
35
36
37
38
32
33
34
35
36
37
38
47
48
49
50
51
52
53
47
48
49
50
51
52
53
62
63
64
65
66
67
68
62
63
64
65
66
67
68
77
78
79
80
81
82
83
77
78
79
80
81
82
83
92
93
94
95
96
97
98
92
93
94
95
96
97
98
107
108
109
110
111
112
113
107
108
109
110
111
112
113
122
123
124
125
126
122
123
124
125
126
Operating voltage
Sounder output
High tone setting volume
nominally 65 to 85dB(A) (Complies with EN54:3)
Low tone setting volume*
Sound pressure level information published in document PP2203 and isolator
operation information published in document PP2090, both available on request
Current consumption at 24V DC
quiescent
switch-on surge
sounder beacon operating
*Low tone setting does not comply to EN54–3 and should not be used for fi re
alarm applications
3
9
10
11
12
13
14
15
9
10
11
12
13
14
15
24
25
26
27
28
29
30
24
25
26
27
28
29
30
39
40
41
42
43
44
45
39
40
41
42
43
44
45
54
55
56
57
58
59
60
54
55
56
57
58
59
60
69
70
71
72
73
74
75
69
70
71
72
73
74
75
84
85
86
87
88
89
90
84
85
86
87
88
89
90
99
100
101
102
103
104
105
99
100
101
102
103
104
105
114
115
116
117
118
119
120
114
115
116
117
118
119
120
17—28V DC
nominally 50 to 65dB(A)
<300μA
1.2mA for 1 sec
8mA