- ページ 28
サーバー Acer Ferrari 1100 SeriesのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Acer Ferrari 1100 Series 30 ページ。 Acer altos 1100 server: user guide
Acer Ferrari 1100 Series にも: ユーザーマニュアル (17 ページ)
Table 1-4
System Error Messages
Message
Memory Error at:
MMMM:SSSS:OOO (W:XXXX,
R:YYYY)
where:
M: MB, S: Segment,
O: Offset,
X/Y: write/read pattern
Memory Size Mismatch
CPU Clock Mismatch
Onboard Serial Port 1 Conflict
Onboard Serial Port 2 Conflict
Onboard Parallel Port Conflict
Pointing Device Error
Pointing Device Interface
Error
Press F1 key to continue or
Ctrl-Alt-Esc for Setup
Real Time Clock Error
Press Esc to turn off NMI, any
key to reboot
1-28
Action
Check DIMMs on the system
board. Contact your dealer.
Check the memory size based on
the system specifications. Check
the internal cable connections. If
you are sure that connections and
values are correct, ignore the
message. If the message
reappears, ask for technical
assistance.
Run Setup and disable the port.
Run Setup and disable the port.
Run Setup and disable the port.
Check and connect pointing
device.
Replace the pointing device or
contact your dealer.
Press
or
+
+
to enter
Setup.
Run Setup and set the time and
date.
Press
to disregard the NMI
error.
Press any other key to reboot the
system.
User's Guide